Harmonization of Quantitative Parenchymal Enhancement in T1 -Weighted Breast MRI

Publication date

2020-11

Authors

van der Velden, Bas H MORCID 0000-0003-3750-2824
van Rijssel, M J
Lena, Beatrice
Philippens, M E PORCID 0000-0003-0205-3459ISNI 0000000387302804
Loo, Claudette E
Ragusi, Max A.A.ORCID 0000-0002-2344-6182
Elias, S. G.ISNI 0000000388198607
Sutton, Elizabeth J
Morris, Elizabeth A
Bartels, L WISNI 0000000388733745

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

Background: Differences in imaging parameters influence computer-extracted parenchymal enhancement measures from breast MRI. Purpose: To investigate the effect of differences in dynamic contrast-enhanced MRI acquisition parameter settings on quantitative parenchymal enhancement of the breast, and to evaluate harmonization of contrast-enhancement values with respect to flip angle and repetition time. Study Type: Retrospective. Phantom/Populations: We modeled parenchymal enhancement using simulations, a phantom, and two cohorts (N = 398 and N = 302) from independent cancer centers. Sequence Field/Strength: 1.5T dynamic contrast-enhanced T 1-weighted spoiled gradient echo MRI. Vendors: Philips, Siemens, General Electric Medical Systems. Assessment: We assessed harmonization of parenchymal enhancement in simulations and phantom by varying the MR parameters that influence the amount of T 1-weighting: flip angle (8°–25°) and repetition time (4–12 msec). We calculated the median and interquartile range (IQR) of the enhancement values before and after harmonization. In vivo, we assessed overlap of quantitative parenchymal enhancement in the cohorts before and after harmonization using kernel density estimations. Cohort 1 was scanned with flip angle 20° and repetition time 8 msec; cohort 2 with flip angle 10° and repetition time 6 msec. Statistical Tests: Paired Wilcoxon signed-rank-test of bootstrapped kernel density estimations. Results: Before harmonization, simulated enhancement values had a median (IQR) of 0.46 (0.34–0.49). After harmonization, the IQR was reduced: median (IQR): 0.44 (0.44–0.45). In the phantom, the IQR also decreased, median (IQR): 0.96 (0.59–1.22) before harmonization, 0.96 (0.91–1.02) after harmonization. Harmonization yielded significantly (P < 0.001) better overlap in parenchymal enhancement between the cohorts: median (IQR) was 0.46 (0.37–0.58) for cohort 1 vs. 0.37 (0.30–0.44) for cohort 2 before harmonization (57% overlap); and 0.35 (0.28–0.43) vs.0.37 (0.30–0.44) after harmonization (85% overlap). Data Conclusion: The proposed practical harmonization method enables an accurate comparison between patients scanned with differences in imaging parameters. Level of Evidence: 3. Technical Efficacy Stage: 4.

Keywords

Radiology Nuclear Medicine and imaging, Journal Article

Citation

van der Velden, B H M, van Rijssel, M J, Lena, B, Philippens, M E P, Loo, C E, Ragusi, M A A, Elias, S G, Sutton, E J, Morris, E A, Bartels, L W & Gilhuijs, K G A 2020, 'Harmonization of Quantitative Parenchymal Enhancement in T1 -Weighted Breast MRI', Journal of Magnetic Resonance Imaging, vol. 52, no. 5, pp. 1374-1382. https://doi.org/10.1002/jmri.27244