Dosimetry of [177Lu]Lu-PSMA therapy in a hemodialysis patient: a case study

Publication date

2026-12

Authors

Hendriks, A.D.
Abrahams, Alferso CISNI 0000000397254068
van Rooij, RobISNI 000000039182607X
Verkaar, Fleur G.M.
Dingemans, Martijn
Bemelmans, John L.M.
Mui, Kwok Wai
de Jong, Hugo W A MORCID 0000-0002-3000-8316
Lam, MarnixORCID 0000-0002-4902-9790

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Background: In this case study, we share our experience on the treatment of a patient with [177Lu]Lu-PSMA for metastatic castration-resistant prostate cancer and comorbid kidney failure. Since a poor kidney function impacts [177Lu]Lu-PSMA clearance, the aim of this study was to carefully monitor the radiation dose to the organs-at-risk, and measure the activity distribution during hemodialysis sessions, by imaging, blood sampling and dialysate sampling. Case presentation: A 72-year-old patient received a total of five cycles of approximately 7.4 GBq [177Lu]Lu-PSMA-I&T, with an interval of 5–7 weeks per cycle. The radiation dose per cycle (mean ± SD) was measured for different regions: total body 0.51 ± 0.06 Gy, liver (incl. tumours) 5.6 ± 0.5 Gy, kidney (single, poor function) 3.3 ± 0.4 Gy, salivary glands 5.5 ± 0.7 Gy, and bone marrow 0.41 ± 0.07 Gy. Hemodialysis was continued three times a week. Precautions for radiation protection were taken for the first hemodialysis session 20 h after [177Lu]Lu-PSMA administration, which took place at the radioligand therapy nursery unit. Blood and dialysate samples, collected during hemodialysis, showed a drop of the activity concentration in the blood of the patient (32% in 3 h), and a partial return of activity to the blood (rebound effect) after the end of the hemodialysis treatment. The radiation dose to the bone marrow of the hemodialysis patient was elevated (by a factor of two as compared to literature), but stayed below dose thresholds for severe deterministic side effects. Conclusions: Despite the preexisting kidney failure of a hemodialysis patient, the carefully monitored radiation dose of [177Lu]Lu-PSMA therapy remained below safe dose thresholds and no signs of severe hematotoxicity were observed.

Keywords

Bone marrow, Dialysis, Dosimetry, Lu177, PSMA, Radioligand therapy, Radionuclide, RLT, Radiology Nuclear Medicine and imaging

Citation

Hendriks, A D, Abrahams, A C, van Rooij, R, Verkaar, F G M, Dingemans, M, Bemelmans, J L M, Mui, K W, de Jong, H W A M & Lam, M G E H 2026, 'Dosimetry of [ 177 Lu]Lu-PSMA therapy in a hemodialysis patient : a case study', EJNMMI Research, vol. 16, no. 1, 72. https://doi.org/10.1186/s13550-026-01433-9