Qualitative tests of remote eyetracker recovery and performance during head rotation

Publication date

2015-09

Authors

Hessels, Roy S.ISNI 0000000492511886
Cornelissen, Tim H.W.ISNI 0000000493258771
Kemner, ChantalISNI 0000000397189075
Hooge, Ignace T.C.ISNI 0000000390565613

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

taverne

Abstract

What are the decision criteria for choosing an eyetracker? Often the choice is based on specifications by the manufacturer of the validity (accuracy) and reliability (precision) of measurements that can be achieved using a particular eyetracker. These specifications are mostly achieved under optimal conditions-for example, by using an artificial eye or trained participants fixed in a chinrest. Research, however, does not always take place in optimal conditions: For instance, when investigating eye movements in infants, school children, and patient groups with disorders such as attention-deficit hyperactivity disorder, it is practically impossible to restrict movement. We modeled movements often seen in infant research in two behaviors: (1) looking away from and back to the screen, to investigate eyetracker recovery, and (2) head orientations, to investigate eyetracker performance with nonoptimal orientations of the eyes. We investigated how eight eyetracking setups by three manufacturers (SMI, Tobii, and LC Technologies) coped with these modeled behaviors in adults. We report that the tested SMI eyetrackers dropped in sampling frequency when the eyes were not visible to the eyetracker, whereas the other systems did not, and discuss the potential consequences thereof. Furthermore, we report that the tested eyetrackers varied in their rates of data loss and systematic offsets during shifted head orientations. We conclude that (prospective) eye-movement researchers who cannot restrict movement or nonoptimal head orientations in their participants might benefit from testing their eyetracker in nonoptimal conditions. Additionally, researchers should be aware of the data loss and inaccuracies that might result from nonoptimal head orientations.

Keywords

Eyetracking, Head movement, Head orientation, Developmental studies, Data quality, Taverne

Citation

Hessels, R S, Cornelissen, T H W, Kemner, C & Hooge, I T C 2015, 'Qualitative tests of remote eyetracker recovery and performance during head rotation', Behavior Research Methods, vol. 47, no. 3, pp. 848-859. https://doi.org/10.3758/s13428-014-0507-6