Interobserver variation in tumor delineation of liver metastases using Magnetic Resonance Imaging

Publication date

2024-04

Authors

Peltenburg, Julia E.
Hosni, Ali
Bahij, Rana
Boeke, Simon
Braam, Pètra M.
Hall, William A.
Intven, Martijn PwORCID 0000-0002-5068-5517ISNI 0000000393019546
Nicosia, Luca
Sonke, Jan Jakob
Witte, Marnix

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Background and purpose: Magnetic Resonance Imaging (MRI) guided stereotactic body radiotherapy (SBRT) of liver metastases is an upcoming high-precision non-invasive treatment. Interobserver variation (IOV) in tumor delineation, however, remains a relevant uncertainty for planning target volume (PTV) margins. The aims of this study were to quantify IOV in MRI-based delineation of the gross tumor volume (GTV) of liver metastases and to detect patient-specific factors influencing IOV. Materials and methods: A total of 22 patients with liver metastases from three primary tumor origins were selected (colorectal(8), breast(6), lung(8)). Delineation guidelines and planning MRI-scans were provided to eight radiation oncologists who delineated all GTVs. All delineations were centrally peer reviewed to identify outliers not meeting the guidelines. Analyses were performed both in- and excluding outliers. IOV was quantified as the standard deviation (SD) of the perpendicular distance of each observer's delineation towards the median delineation. The correlation of IOV with shape regularity, tumor origin and volume was determined. Results: Including all delineations, average IOV was 1.6 mm (range 0.6–3.3 mm). From 160 delineations, in total fourteen single delineations were marked as outliers after peer review. After excluding outliers, the average IOV was 1.3 mm (range 0.6–2.3 mm). There was no significant correlation between IOV and tumor origin or volume. However, there was a significant correlation between IOV and regularity (Spearman's ρs = -0.66; p = 0.002). Conclusion: MRI-based IOV in tumor delineation of liver metastases was 1.3–1.6 mm, from which PTV margins for IOV can be calculated. Tumor regularity and IOV were significantly correlated, potentially allowing for patient-specific margin calculation.

Keywords

GTV, Interobserver variation (IOV), Liver metastases, MRI, Quality assurance (QA), Tumor delineation, Radiation, Oncology, Radiology Nuclear Medicine and imaging

Citation

Peltenburg, J E, Hosni, A, Bahij, R, Boeke, S, Braam, P M, Hall, W A, Intven, M P W, Nicosia, L, Sonke, J J, Witte, M, Nowee, M E & Janssen, T 2024, 'Interobserver variation in tumor delineation of liver metastases using Magnetic Resonance Imaging', Physics and Imaging in Radiation Oncology, vol. 30, 100592. https://doi.org/10.1016/j.phro.2024.100592