Comparative accuracy evaluation of patient-specific 3D-printed guide and neuronavigation for ventriculoperitoneal shunt in dogs: a dual-phase ex vivo and in vivo study

Publication date

2025-11-14

Authors

Jeon, YoungJin
Cho, Cheongwoon
Jeong, Jaemin
Meij, BjörnORCID 0000-0002-0165-1169ISNI 0000000388662836
Lee, Haebeom

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

cc_by

Abstract

BACKGROUND: Ventriculoperitoneal shunting (VPS) is an effective treatment for canine hydrocephalus, but complications related to ventricular catheter (VC) misplacement remain a concern. Although neuronavigation improves accuracy, its cost and complexity limit veterinary use. Patient-specific 3D-printed guiding systems (PS-3DGS) offer a potential alternative. OBJECTIVES: To compare the accuracy and feasibility of PS-3DGS compared to electromagnetic neuronavigation for VC placement in 3D-printed canine cranio-ventricular models (CVMs) and Beagle dogs. ANIMALS AND STUDY DESIGN: Ten 3D-printed CVMs ( ex vivo study) and five experimental Beagle dogs ( in vivo study). METHODS: VC placement was performed using PS-3DGS and neuronavigation in CVMs and experimental animals. Accuracy was assessed by the distance from the VC tip to the foramen of Monro (DFM), tip coordinates (X, Y, Z axes), tip placement error, intraventricular insertion length (IIL), and catheter contact with the ventricular wall (VVL). Intraoperative procedural time and anatomical variables, including skull and cranial indices, were also analyzed. RESULTS: PS-3DGS showed no significant difference in DFM compared to neuronavigation in CVMs and Beagle dogs. PS-3DGS achieved significantly lower VVL and reduced procedural time than neuronavigation in the CVM study ( p = 0.011 and p = 0.039, respectively). In dogs, DFM with PS-3DGS was comparable to both neuronavigation and the ex vivo results. Entry point error correlated negatively with cranial index (r = -0.9, p = 0.037). CONCLUSION: PS-3DGS provided accuracy comparable to neuronavigation while simplifying the procedure. It represents a viable, cost-effective alternative for canine VPS surgery, potentially enhancing catheter placement and reducing complications.

Keywords

hydrocephalus, neuronavigation, patient-specific guides, ventricular catheter, ventriculoperitoneal shunt, General Veterinary

Citation

Jeon, Y, Cho, C, Jeong, J, Meij, B & Lee, H 2025, 'Comparative accuracy evaluation of patient-specific 3D-printed guide and neuronavigation for ventriculoperitoneal shunt in dogs : a dual-phase ex vivo and in vivo study', Frontiers in Veterinary Science, vol. 12, 1665844. https://doi.org/10.3389/fvets.2025.1665844