Evaluating the benefit of PBS vs. VMAT dose distributions in terms of dosimetric sparing and robustness against inter-fraction anatomical changes for pediatric abdominal tumors

Publication date

2019-09

Authors

Guerreiro, Filipa
Zachiu, Cornel
Seravalli, EnricaORCID 0000-0001-5983-2256ISNI 0000000047208248
Ribeiro, Cássia O
Janssens, Geert O.ORCID 0000-0002-0331-713X
Ries, M.
de Senneville, B. Denis
Maduro, John H.
Brouwer, Charlotte L
Korevaar, Erik W

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

BACKGROUND AND PURPOSE: To evaluate the dosimetric sparing and robustness against inter-fraction anatomical changes between photon and proton dose distributions for children with abdominal tumors. MATERIAL AND METHODS: Volumetric modulated arc therapy (VMAT) and intensity-modulated pencil beam scanning (PBS) proton dose distributions were calculated for 20 abdominal pediatric cases (average 3, range 1-8 years). VMAT plans were based on a full-arc while PBS plans on 2-3 posterior-oblique irradiation fields. Plans were robustly optimized on a patient-specific internal target volume (ITV) using a uniform 5 mm set-up uncertainty. Additionally, for the PBS plans a ± 3% proton range uncertainty was accounted for. Fractional dose re-calculations were performed using the planning computed tomography (CT) deformably registered to the daily cone-beam CT (CBCT) images. Fractional doses were accumulated rigidly. Planned and CBCT accumulated VMAT and PBS dose distributions were compared using dose-volume histogram (DVH) parameters. RESULTS: Significant better sparing of the organs at risk with a maximum reduction in the mean dose of 40% was achieved with PBS. Mean ITV DVH parameters differences between planned and CBCT accumulated dose distributions were smaller than 0.5% for both VMAT and PBS. However, the ITV coverage (V95% > 99%) was not reached for one patient for the accumulated VMAT dose distribution. CONCLUSIONS: For pediatric patients with abdominal tumors, improved dosimetric sparing was obtained with PBS compared to VMAT. In addition, PBS delivered by posterior-oblique irradiation fields demonstrated to be robust against anatomical inter-fraction changes. Compared to PBS, daily anatomical changes proved to affect the target coverage of VMAT dose distributions to a higher extent.

Keywords

Pediatric IGRT, Pediatric abdominal tumors, Robust pencil beam scanning, Proton therapy, VMAT, Inter-fraction anatomical changes, Taverne, Journal Article

Citation

Guerreiro, F, Zachiu, C, Seravalli, E, Ribeiro, C O, Janssens, G O, Ries, M, de Senneville, B D, Maduro, J H, Brouwer, C L, Korevaar, E W, Knopf, A C & Raaymakers, B W 2019, 'Evaluating the benefit of PBS vs. VMAT dose distributions in terms of dosimetric sparing and robustness against inter-fraction anatomical changes for pediatric abdominal tumors', Radiotherapy & Oncology, vol. 138, pp. 158-165. https://doi.org/10.1016/j.radonc.2019.06.025