Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy
Files
Publication date
2022-02
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
cc_by_nc
Abstract
AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms in ARVC. METHODS AND RESULTS: We classified 617 definite ARVC patients (38.5 ± 15.1 years, 52.4% male, 39.2% prior sustained VA) according to four algorithms. Clinical performance was evaluated by sensitivity, specificity, ROC-analysis, and decision curve analysis for any sustained VA and for fast VA (>250 b.p.m.). During 6.4 [2.8-11.5] years follow-up, 282 (45.7%) patients experienced any sustained VA, and 63 (10.2%) fast VA. For any sustained VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (94.0-97.8% vs. 76.7-83.5%), but lower specificity (15.9-32.0% vs. 42.7%-60.1%). Similarly, for fast VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (95.2-97.1% vs. 76.7-78.4%) but lower specificity (42.7-43.1 vs. 76.7-78.4%). Decision curve analysis showed ITFC and mITFC to be superior for a 5-year sustained VA risk ICD indication threshold between 5-25% or 2-9% for fast VA. CONCLUSION: The ITFC and mITFC provide the highest protection rates, whereas AHA and HRS decrease unnecessary ICD placements. ITFC or mITFC should be used if we consider the 5-year threshold for ICD indication to lie within 5-25% for sustained VA or 2-9% for fast VA. These data will inform decision-making for ICD placement in ARVC.
Keywords
Arrhythmogenic right ventricular cardiomyopathy, Implantable cardioverter-defibrillator, Prognosis, Risk stratification, Ventricular arrhythmias, Cardiology and Cardiovascular Medicine, Physiology (medical), Journal Article
Citation
Bosman, L P, Nielsen Gerlach, C L, Cadrin-Tourigny, J, Orgeron, G, Tichnell, C, Murray, B, Bourfiss, M, van der Heijden, J F, Yap, S-C, Zeppenfeld, K, van den Berg, M P, Wilde, A A M, Asselbergs, F W, Tandri, H, Calkins, H, van Tintelen, J P, James, C A & Te Riele, A S J M 2022, 'Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy', Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, vol. 24, no. 2, pp. 296-305. https://doi.org/10.1093/europace/euab162