Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis

Publication date

2017-08-12

Authors

Struik, T
Jaspers, J E NISNI 0000000419441252
Besselink, Nick J
van Roermund, P. M.ISNI 0000000368955332
Plomp, S
Rudert, M J
Lafeber, Floris P J GISNI 0000000393082668
Mastbergen, SimonORCID 0000-0002-8825-6486ISNI 000000039429067X

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

BACKGROUND: Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. METHODS: Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. FINDINGS: The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. INTERPRETATION: Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted.

Keywords

Articulating, Biomechanical testing, Joint distraction, Joint specific, Knee osteoarthritis, Personalized, Taverne, Journal Article

Citation

Struik, T, Jaspers, J E N, Besselink, N J, van Roermund, P M, Plomp, S, Rudert, M J, Lafeber, F P J G & Mastbergen, S C 2017, 'Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis', Clinical biomechanics, vol. 49, pp. 40-47. https://doi.org/10.1016/j.clinbiomech.2017.08.002