Systematic evaluation of design features enables efficient selection of Π electron-stabilized polymeric micelles

Publication date

2020-06-30

Authors

Sheybanifard, Maryam
Beztsinna, NataliiaISNI 0000000505885108
Bagheri, MahsaISNI 0000000492835776
Buhl, Eva Miriam
Bresseleers, JaleesaISNI 0000000517902198
Varela-Moreira, AidaISNI 0000000511632801
Shi, YangISNI 0000000527247967
van Nostrum, Cornelus FISNI 0000000396379707
van der Pluijm, Gabri
Storm, GertISNI 0000000042534976

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

Abstract

Polymeric micelles (PM) based on poly(ethylene glycol)-b-poly(N-2-benzoyloxypropyl methacrylamide) (mPEG-b-p(HPMA-Bz)) loaded with paclitaxel (PTX-PM) have shown promising results in overcoming the suboptimal efficacy/toxicity profile of paclitaxel. To get insight into the stability of PTX-PM formulations upon storage and to optimize their in vivo tumor-targeted drug delivery properties, we set out to identify a lead PTX-PM formulation with the optimal polymer composition. To this end, PM based on four different mPEG5k-b-p(HPMA-Bz) block copolymers with varying molecular weight of the hydrophobic block (17-3 kDa) were loaded with different amounts of PTX. The hydrodynamic diameter was 52 ± 1 nm for PM prepared using polymers with longer hydrophobic blocks (mPEG5k-b-p(HPMA-Bz)17k and mPEG5k-b-p(HPMA-Bz)10k) and 39 ± 1 nm for PM composed of polymers with shorter hydrophobic blocks (mPEG5k-b-p(HPMA-Bz)5k and mPEG5k-b-p(HPMA-Bz)3k). The best storage stability and the slowest PTX release was observed for PM with larger hydrophobic blocks. On the other hand, smaller sized PM of shorter mPEG5k-b-p(HPMA-Bz)5k showed a better tumor penetration in 3D spheroids. Considering better drug retention capacity of the mPEG5k-b-p(HPMA-Bz)17k and smaller size of the mPEG5k-b-p(HPMA-Bz)5k as two desirable design features, we argue that PM based on these two polymers are the lead candidates for further in vivo studies.

Keywords

Polymeric micelles, π-π stacking interactions, Paclitaxel, In vitro release kinetics, 3D cell culture, Storage stability, Taverne

Citation

Sheybanifard, M, Beztsinna, N, Bagheri, M, Buhl, E M, Bresseleers, J, Varela-Moreira, A, Shi, Y, van Nostrum, C F, van der Pluijm, G, Storm, G, Hennink, W E, Lammers, T & Metselaar, J M 2020, 'Systematic evaluation of design features enables efficient selection of Π electron-stabilized polymeric micelles', International Journal of Pharmaceutics, vol. 584, 119409. https://doi.org/10.1016/j.ijpharm.2020.119409