A Theoretical and Experimental Study to Optimize Cell Differentiation in a Novel Intestinal Chip

Publication date

2020-07-24

Authors

Langerak, Nicky
Ahmed, Haysam M.M.ISNI 0000000493352151
Li, Yang
Sweet, Igor R.ISNI 0000000492816954
Eslami Amirabadi, HosseinISNI 0000000492853253
Malda, JosORCID 0000-0002-9241-7676ISNI 0000000388144393
Masereeuw, RosalindeORCID 0000-0002-1560-1074ISNI 0000000369326917
Roij, René vanISNI 0000000392993654

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

cc_by

Abstract

Microphysiological systems have potential as test systems in studying the intestinal barrier, in which shear stress is critical for the differentiation of Caco-2 cells into enterocytes. The most commonly used in vitro gut model for intestinal barrier studies is based on trans-well cultures. Albeit useful, these culture systems lack physiological shear stress which is believed to be critical for the differentiation of Caco-2 cells into enterocytes and to form tight monolayers. Conversely, organ-on-chip models have presented themselves as a promising alternative since it provides cells with the required shear stress. To this end, a novel biocompatible 3D-printed microfluidic device was developed. In this device, Caco-2 cells were seeded under physiologically-relevant unidirectional shear stress and compared to cells cultured under gravity-driven flow. Using numerical studies, the flow rate that corresponds to the required shear stress was calculated. Experimental tests were conducted to verify the effect of this on cell differentiation. The experiments clearly showed an enhancement of cell differentiation potential in a unidirectional physiologically-relevant pump-driven flow system (PDFS) as opposed to the simpler bidirectional gravity-driven flow system (GDFS). Additionally, computational modeling of an adapted design confirmed its ability to supply all cells with a more homogeneous shear stress, potentially further enhancing their differentiation. The shear stress in the adapted design can be well-approximated with analytic methods, thus allowing for efficient predictions for all parameter values in the system. The developed novel microfluidic device led to the formation of a tighter monolayer and enhanced functional properties of the differentiated Caco-2 cells, which presents a promising tool for preclinical in vitro testing of drugs in an animal-free platform.

Keywords

3D printing, cell differentiation, gut-on-chip, numerical computation, shear stress, Biotechnology, Bioengineering, Histology, Biomedical Engineering

Citation

Langerak, N, Ahmed, H M M, Li, Y, Middel, I R, Eslami Amirabadi, H, Malda, J, Masereeuw, R & van Roij, R 2020, 'A Theoretical and Experimental Study to Optimize Cell Differentiation in a Novel Intestinal Chip', Frontiers in Bioengineering and Biotechnology, vol. 8, 763. https://doi.org/10.3389/fbioe.2020.00763