Double delay alternating with nutation for tailored excitation facilitates banding-free isotropic high-resolution intracranial vessel wall imaging

Publication date

2021-09

Authors

Coolen, Bram F
Schoormans, Jasper
Gilbert, Guillaume
Kooreman, Ernst S
de Winter, Naomi
Viessmann, Olivia
Zwanenburg, J. J.M.ORCID 0000-0002-4282-5719
Majoie, Charles B.L.M.
Strijkers, Gustav J
Nederveen, Aart J

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

The purpose of this study was to evaluate the use of a double delay alternating with nutation for tailored excitation (D-DANTE)-prepared sequence for banding-free isotropic high-resolution intracranial vessel wall imaging (IC-VWI) and to compare its performance with regular DANTE in terms of signal-to-noise ratio (SNR) as well as cerebrospinal fluid (CSF) and blood suppression efficiency. To this end, a D-DANTE-prepared 3D turbo spin echo sequence was implemented by interleaving two separate DANTE pulse trains with different RF phase-cycling schemes, but keeping all other DANTE parameters unchanged, including the total number of pulses and total preparation time. This achieved a reduction of the banding distance compared with regular DANTE enabling banding-free imaging up to higher resolutions. Bloch simulations assuming static vessel wall and flowing CSF spins were performed to compare DANTE and D-DANTE in terms of SNR and vessel wall/CSF contrast. Similar image quality measures were assessed from measurements on 13 healthy middle-aged volunteers. Both simulation and in vivo results showed that D-DANTE had only slightly lower vessel wall/CSF and vessel wall/blood contrast-to-noise ratio values compared with regular DANTE, which originated from a 10%-15% reduction in vessel wall SNR but not from reduced CSF or blood suppression efficiency. As anticipated, IC-VWI acquisitions showed that D-DANTE can successfully remove banding artifacts compared with regular DANTE with equal scan time or DANTE preparation length. Moreover, application was demonstrated in a patient with an intracranial aneurysm, indicating improved robustness to slow flow artifacts compared with clinically available 3D turbo spin echo scans. In conclusion, D-DANTE provides banding artifact-free IC-VWI up to higher isotropic resolutions compared with regular DANTE. This allows for a more flexible choice of DANTE preparation parameters in high-resolution IC-VWI protocols.

Keywords

atherosclerosis, CSF suppression, DANTE, intracranial vessel wall imaging, Molecular Medicine, Radiology Nuclear Medicine and imaging, Spectroscopy, Journal Article

Citation

Coolen, B F, Schoormans, J, Gilbert, G, Kooreman, E S, de Winter, N, Viessmann, O, Zwanenburg, J J M, Majoie, C B L M, Strijkers, G J, Nederveen, A J & Siero, J C W 2021, 'Double delay alternating with nutation for tailored excitation facilitates banding-free isotropic high-resolution intracranial vessel wall imaging', NMR in Biomedicine, vol. 34, no. 9, e4567. https://doi.org/10.1002/nbm.4567