Seminal vesicle intrafraction motion during the delivery of radiotherapy sessions on a 1.5 T MR-Linac

Publication date

2021-09

Authors

De, D. M. Muinck Keizer
Willigenburg, Thomas
van der Voort van Zyp, Jochem R NISNI 0000000393775683
Raaymakers, Bas WORCID 0000-0002-8036-6808ISNI 0000000392005337
Lagendijk, J J WISNI 0000000393637862
de Boer, Johannes C J

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Purpose To evaluate seminal vesicle (SV) intrafraction motion using cinematic magnetic resonance imaging (cine-MR) during the delivery of online adaptive MR-Linac radiotherapy fractions, in preparation of MR-guided extremely hypofractionated radiotherapy for intermediate to high-risk prostate cancer patients. Material and Methods Fifty prostate cancer patients were treated with 5 × 7.25 Gy on a 1.5 Tesla MR-Linac. 3D Cine-MR imaging was started simultaneously and acquired over the full beam-on period. Intrafraction motion in this cine-MR was determined for each SV separately with a previously validated soft-tissue contrast-based tracking algorithm. Motion statistics and coverage probability for the SVs and prostate were determined based on the obtained results. Results SV motion was automatically determined during the beam-on period (approx. 10 min) for 247 fractions. SV intrafraction motion shows larger spread than prostate intrafraction motion and increases over time. This difference is especially evident in the anterior and cranial translation directions. Significant difference in rotation about the left–right axis was found, with larger rotation for the SVs than the prostate. Intra-fraction coverage probability of 99% can be achieved when using 5 mm isometric expansion for the left and right SV and 3 mm for the prostate. Conclusion This is the first study to investigate SV intrafraction motion during MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and SV tracking during RT is feasible with beam-on. The tracking method as described may be used as input for a fast replanning algorithm, which allows for intrafraction plan adaptation.

Keywords

Cine-MR, Intrafraction motion, MR-Linac, MR-guided radiotherapy, Prostate cancer, Seminal vesicles, Hematology, Oncology, Radiology Nuclear Medicine and imaging

Citation

De, D M M K, Willigenburg, T, Van, J R N D V V Z, Raaymakers, B W, Lagendijk, J J W & De, J C J B 2021, 'Seminal vesicle intrafraction motion during the delivery of radiotherapy sessions on a 1.5 T MR-Linac', Radiotherapy and Oncology, vol. 162, pp. 162-169. https://doi.org/10.1016/j.radonc.2021.07.014