Real-time myocardial landmark tracking for MRI-guided cardiac radio-ablation using Gaussian Processes

Publication date

2023-07-05

Authors

Huttinga, Niek R.F.
Akdag, Osman
Fast, Martin FORCID 0000-0001-9107-4627
Verhoeff, Joost J CORCID 0000-0001-9673-0793ISNI 0000000393929005
Hoesein, Firdaus A. A. MohamedISNI 0000000387296109
van den Berg, CATORCID 0000-0002-5565-6889
Sbrizzi, AlessandroORCID 0000-0003-3276-4542ISNI 0000000396833383
Mandija, StefanoORCID 0000-0002-4612-5509

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Objective.The high speed of cardiorespiratory motion introduces a unique challenge for cardiac stereotactic radio-ablation (STAR) treatments with the MR-linac. Such treatments require tracking myocardial landmarks with a maximum latency of 100 ms, which includes the acquisition of the required data. The aim of this study is to present a new method that allows to track myocardial landmarks from few readouts of MRI data, thereby achieving a latency sufficient for STAR treatments. Approach.We present a tracking framework that requires only few readouts of k-space data as input, which can be acquired at least an order of magnitude faster than MR-images. Combined with the real-time tracking speed of a probabilistic machine learning framework called Gaussian Processes, this allows to track myocardial landmarks with a sufficiently low latency for cardiac STAR guidance, including both the acquisition of required data, and the tracking inference. Main results.The framework is demonstrated in 2D on a motion phantom, and in vivoon volunteers and a ventricular tachycardia (arrhythmia) patient. Moreover, the feasibility of an extension to 3D was demonstrated by in silico3D experiments with a digital motion phantom. The framework was compared with template matching-a reference, image-based, method-and linear regression methods. Results indicate an order of magnitude lower total latency (<10 ms) for the proposed framework in comparison with alternative methods. The root-mean-square-distances and mean end-point-distance with the reference tracking method was less than 0.8 mm for all experiments, showing excellent (sub-voxel) agreement. Significance.The high accuracy in combination with a total latency of less than 10 ms-including data acquisition and processing-make the proposed method a suitable candidate for tracking during STAR treatments. Additionally, the probabilistic nature of the Gaussian Processes also gives access to real-time prediction uncertainties, which could prove useful for real-time quality assurance during treatments.

Keywords

MR-linac, STAR, magnetic resonance imaging, motion management, radiotherapy, real-time tracking, stereotactic arrhythmia radio-ablation, Taverne, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging

Citation

Huttinga, N R F, Akdag, O, Fast, M F, Verhoeff, J J C, Mohamed Hoesein, F A A, Van den Berg, C A T, Sbrizzi, A & Mandija, S 2023, 'Real-time myocardial landmark tracking for MRI-guided cardiac radio-ablation using Gaussian Processes', Physics in medicine and biology, vol. 68, no. 14, 145001. https://doi.org/10.1088/1361-6560/ace023