Acquisition matters - how do scan parameters affect apparent diffusion coefficient estimates in pediatric rhabdomyosarcoma

Publication date

2025-07

Authors

Chatziantoniou, CyranoORCID 0000-0002-8671-2580
van Ewijk, Roelof
Adams, Madeleine
Bertolini, Patrizia
Bisogno, Gianni
Bouhamama, Amine
Caro-Dominguez, Pablo
Charon, Valérie
Coma, Ana
Dandis, Rana

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background: The apparent diffusion coefficient (ADC) derived from diffusion-weighted imaging (DWI) is a potential biomarker for treatment response in pediatric rhabdomyosarcoma. Due to its rarity, investigations into this marker require multicenter approaches, which can result in variability in acquisition parameters. Objective: To evaluate the impact of different acquisition parameters on ADC estimates in a multicenter dataset of rhabdomyosarcoma patients. Materials and methods: We included 114 pediatric and adolescent rhabdomyosarcoma patients from 22 treatment centers (195 scans). Median age: 6.0 years (0.3–21.8). We evaluated the impact of voxel size, (number of) b-values, and echo time on tumor ADC values. The effect of the highest b-value was separately investigated on a subset of scans with five or more b-values. Results: We observed a large variability in key acquisition parameters in the overall cohort, and for individual imaging centers. No parameter showed a significant effect on ADC estimates of the whole cohort when corrected for multiple-comparisons. Decreasing the highest b-value within the same acquisition caused ADC to decrease on average by 2.8% per 100 s mm-2. Differing b-values between scans at diagnosis and treatment response yielded significant changes in the longitudinal ADC for each patient (P<0.05). Conclusion: While we observed wide variation of acquisition parameters within a multicenter cohort, this did not lead to significant cross-sectional differences of tumor ADC. However, we found that modifying the highest b-value between baseline and follow-up can impact longitudinal ADC estimates. As such, we recommend the highest b-value to remain constant. This retrospective study was reviewed and approved by the Internal Review Board (UMC Utrecht, reference ID: 18-412).

Keywords

Adolescent, Child, Diffusion magnetic resonance imaging, Rhabdomyosarcoma, Journal Article

Citation

Chatziantoniou, C, van Ewijk, R, Adams, M, Bertolini, P, Bisogno, G, Bouhamama, A, Caro-Dominguez, P, Charon, V, Coma, A, Dandis, R, Devalck, C, De Donno, G, Ferrari, A, Fiocco, M, Gallego, S, Giraudo, C, Glosli, H, Ter Horst, S A J, Jenney, M, Klein, W M, Leemans, A, Leseur, J, Mandeville, H C, McHugh, K, Merks, J H M, Minard-Colin, V, Moalla, S, Morosi, C, Orbach, D, Ording Müller, L-S, Pace, E, Di Paolo, P L, Perruccio, K, Quaglietta, L, Renard, M, van Rijn, R R, Ruggiero, A, Sirvent, S I, Schoot, R A & De Luca, A 2025, 'Acquisition matters - how do scan parameters affect apparent diffusion coefficient estimates in pediatric rhabdomyosarcoma', Pediatric radiology, vol. 55, no. 8, pp. 1598-1610. https://doi.org/10.1007/s00247-025-06263-w