Driving restrictions for dutch patients with an implantable cardioverter defibrillator compliance and associated factors

Publication date

2018-02-01

Authors

Jongejan, N.
Timmermans, Ivy
Elders, J.
Meijer, K.
Meine, MathiasORCID 0000-0002-1102-2155ISNI 0000000369243476
Doevendans, PieterISNI 0000000110574516
Versteeg, HISNI 0000000393818962
Tuinenburg, AntonISNI 0000000391500168

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

Background Dutch patients with an implantable cardioverter defibrillator (ICD) are restricted from driving for two months after implantation or shocks. This requires significant lifestyle adjustments and is one of the primary concerns of ICD patients. Previous studies indicated that compliance with the driving restrictions is poor, but insight in socio-demographic, clinical and psychological factors associated with compliance is limited. Hence, this study aimed to explore compliance with the driving restrictions and associated factors in a large sample of Dutch ICD patients. Method Dutch ICD patients (N = 313) completed an elaborative set of questionnaires at time of implantation and at four months after implantation, assessing socio-demographic, psychological and driving-related characteristics. Clinical data were collected from the patients’ medical records. Results A substantial subgroup (28%) of the patient sample (median age 64 (interquartile range = 55–71), 81% male) reported to have been noncompliant with the driving restrictions. Univariate analysis indicated that noncompliant patients more often considered refusing the ICD due to the restrictions, compared to compliant patients (19% versus 10%, p = 0.02). Multivariate analysis showed that the feeling of understanding the reason behind the driving restrictions was associated with better compliance (odds ratio = 2.16, 95% confidence interval 1.02–4.56, p = 0.04). No other socio-demographic, clinical, psychological or driving-related factors were associated with compliance. Conclusion A large number of ICD patients does not comply with the driving restrictions after implantation. This study emphasised the importance of the patient’s feeling of understanding the reason behind the restrictions.

Keywords

Compliance, Driving restrictions, Implantable cardioverter defibrillator, Cardiology and Cardiovascular Medicine

Citation

Jongejan, N, Timmermans, I, Elders, J, Meijer, K, Meine, M, Doevendans, P A, Versteeg, H & Tuinenburg, A E 2018, 'Driving restrictions for dutch patients with an implantable cardioverter defibrillator compliance and associated factors', Netherlands Heart Journal, vol. 26, no. 2, pp. 69-75. https://doi.org/10.1007/s12471-017-1067-z