The Spring Distraction System for Growth-Friendly Surgical Treatment of Early Onset Scoliosis: A Preliminary Report on Clinical Results and Safety after Design Iterations in a Prospective Clinical Trial

Publication date

2022-07-01

Authors

Tabeling, Casper S.
Lemans, Justin
Top, Anouk
Scholten, E. Pauline
Stempels, Hilde W.
Schlösser, Tom
Ito, Keita
Castelein, RMISNI 0000000392339484
Kruijt, MoyoORCID 0000-0002-5983-5251ISNI 0000000387798520

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background: The Spring Distraction System (SDS) is a dynamic growth-friendly implant to treat early onset scoliosis (EOS). Previous SDS studies showed promising results in terms of curve correction and complication profile. Nevertheless, complications did occur, which led to modifications in the implant design. The main iterations were a larger rod diameter and a more sagittal stable sliding mechanism. The purpose of this study was to investigate the performance of these iterations. Methods: All patients treated with the modified SDS and >1 year follow-up were included. Radiographic outcomes, severe adverse events (SAEs), unplanned returns to the operating room (UPRORs) and health-related quality of life (HRQoL) were investigated. Results: Seventeen EOS patients (three congenital, four idiopathic, nine neuromuscular, one syndromic) were included. Mean age at surgery was 9.5 ± 2.5 years. Similar to the first generation SDS, about 50% initial correction was achieved and maintained, and spinal growth was near physiological. Most importantly, SAEs and UPRORs were diminished and favorable with 0.10/patient/year. In addition, HRQoL increased during the first year postoperatively, indicating the implant was well accepted. Conclusion: These preliminary results indicate that the iterations of the SDS are effective in terms of reducing SAEs and UPRORs and increasing HRQoL in patients with EOS.

Keywords

curve correction, dynamic, early onset scoliosis, growth, growth-friendly, patient-reported outcome measures, severe adverse events, spring distraction system, unplanned returns to the operating room, versatile, General Medicine, Journal Article

Citation

Tabeling, C S, Lemans, J V C, Top, A, Scholten, E P, Stempels, H W, Schlösser, T P C, Ito, K, Castelein, R M & Kruyt, M C 2022, 'The Spring Distraction System for Growth-Friendly Surgical Treatment of Early Onset Scoliosis : A Preliminary Report on Clinical Results and Safety after Design Iterations in a Prospective Clinical Trial', Journal of Clinical medicine, vol. 11, no. 13, 3747. https://doi.org/10.3390/jcm11133747