Critical appraisal of multidimensional CT measurements following acute open repair of type A aortic dissection
Publication date
2020-03-01
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
cc_by
Abstract
INTRODUCTION: To identify patients with aneurysmal degeneration of the native aorta following type A aortic dissection (TAAD), reproducible serial measurements of aortic dimensions are critical. We used a systematic workflow for measuring aortic geometry following TAAD, using computed tomography angiography data, and test its reproducibility. METHODS: The workflow for aortic measurements included centerline generation, luminal diameter, and area measurement at six anatomically defined locations along the aorta and luminal volumetric measurements in the descending aorta. Two independent observers measured the aortic geometry in 20 surgically repaired TAAD patients, preoperatively and at 3 months follow-up. To test reproducibility, intraobserver and interobserver agreement scores were analyzed using a concordance correlation coefficient (CCC). RESULTS: The interobserver agreement scores of the diameter, area, and volumetric measurements in the descending aorta were acceptable. The agreement scores of the area measurements were highest, with CCCs ranging from 0.909 to 0.984. Luminal diameter measurements scored lower than luminal area measurements and were least reproducible at the mid aortic arch (CCC < 0.886). Overall, intraobserver agreement scores were better than interobserver agreement scores (SD of mean difference was 1.89 vs 1.94 for intraobserver vs interobserver diameter measurements, and 0.61 vs 0.66 for area measurements). CONCLUSION: Although overall reproducibility was acceptable in descending aortic measurements, our results show that it remains challenging to reliably measure luminal diameters, compared with areas. To aid identification of early adverse remodeling following acute TAAD, novel two- and three-dimensional measurement techniques are needed that capture locoregional changes in the false lumen and true lumen morphology more accurately.
Keywords
3D imaging, angiographic computed tomography, diameter, false lumen, interrater agreement, morphology, type A dissection
Citation
Houben, I B, van Bakel, T M J, Burris, N S, Moll, F L, van Herwaarden, J A & Patel, H J 2020, 'Critical appraisal of multidimensional CT measurements following acute open repair of type A aortic dissection', Journal of Cardiac Surgery, vol. 35, no. 3, pp. 634-644. https://doi.org/10.1111/jocs.14446