Prolonged Electromechanical Interval Unmasks Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy in the Subclinical Stage

Publication date

2016

Authors

Mast, Thomas P.
Teske, Arco JISNI 0000000396645403
Te Riele, Anneline S J M
Groeneweg, Judith A.
Van Der Heijden, Jeroen F.ISNI 0000000396634202
Velthuis, Birgitta KORCID 0000-0002-2542-9474ISNI 0000000395231874
Loh, PeterISNI 0000000357477339
Doevendans, PieterISNI 0000000110574516
van Veen, Toon A BISNI 0000000394849488
Dooijes, DennisISNI 0000000389750790

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

INTRODUCTION: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is characterized by high incidence of ventricular arrhythmias. Overt ARVD/C is preceded by a subclinical stage with lack of detectable ECG and structural abnormalities. Activation delay is present before structural abnormalities and is a hallmark of arrhythmogenesis. Deformation imaging may unmask activation delay in the subclinical stage. METHODS: Three groups were compared: (1) mutation-positive definite ARVD/C-patients fulfilling 2010 Task Force criteria (TFC) (n = 44); (2) asymptomatic mutation carriers not fulfilling TFC and without history of ventricular arrhythmias (n = 31); and (3) controls (n = 30). All underwent ECG and echocardiographic deformation imaging. As a surrogate for local activation delay the electromechanical interval (EMI) was measured, defined as time between onset-QRS and onset of shortening. Arrhythmic outcome (PVC-count, VT) of asymptomatic mutation carriers was correlated with EMI and ECG TFC. RESULTS: In definite ARVD/C-patients, EMI was prolonged in all lateral RV segments. In asymptomatic mutation carriers, prolonged EMI was detected in the subtricuspid area in 14/31. Terminal activation duration ≥55 milliseconds (definition: supporting information) was the only ECG abnormality in this group (8/31). After a mean follow-up of 4.2 ± 3.1 years 10/31 asymptomatic mutation carriers experienced arrhythmic outcome. Prolonged subtricuspid EMI was the only parameter significantly associated with arrhythmogenesis during follow-up. CONCLUSION: In ARVD/C-patients, EMI prolongation was present throughout the RV. In asymptomatic mutation carriers, prolonged EMI in the subtricuspid area is often detected without any additional abnormalities. These preliminary results indicate that prolonged EMI is a new parameter unmasking activation delay in the subclinical stage and may contribute to risk stratification.

Keywords

activation delay, arrhythmogenic right ventricular dysplasia/cardiomyopathy, echocardiography, diagnosis, deformation imaging, risk stratification, ventricular arrhythmias, Taverne, Journal Article, Research Support, Non-U.S. Gov't

Citation

Mast, T P, Teske, A J, Te Riele, A S, Groeneweg, J A, Van Der Heijden, J F, Velthuis, B K, Loh, P, Doevendans, P A, Van Veen, T A, Dooijes, D, De Bakker, J M, Hauer, R N & Cramer, M J 2016, 'Prolonged Electromechanical Interval Unmasks Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy in the Subclinical Stage', Journal of Cardiovascular Electrophysiology, vol. 27, no. 3, pp. 303-314. https://doi.org/10.1111/jce.12882