Detectability and accuracy of computational measurements of in-silico and physical representations of enlarged perivascular spaces from magnetic resonance images

Publication date

2024-03

Authors

Duarte Coello, Roberto
Valdés Hernández, Maria Del C
Zwanenburg, Jaco J MORCID 0000-0002-4282-5719
van der Velden, Moniek
Kuijf, Hugo J.ORCID 0000-0001-6997-9059ISNI 0000000393308567
De Luca, AlbertoORCID 0000-0002-2553-7299
Moyano, José Bernal
Ballerini, Lucia
Chappell, Francesca M
Brown, Rosalind

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

BACKGROUND: Magnetic Resonance Imaging (MRI) visible perivascular spaces (PVS) have been associated with age, decline in cognitive abilities, interrupted sleep, and markers of small vessel disease. But the limits of validity of their quantification have not been established. NEW METHOD: We use a purpose-built digital reference object to construct an in-silico phantom for addressing this need, and validate it using a physical phantom. We use cylinders of different sizes as models for PVS. We also evaluate the influence of 'PVS' orientation, and different sets of parameters of the two vesselness filters that have been used for enhancing tubular structures, namely Frangi and RORPO filters, in the measurements' accuracy. RESULTS: PVS measurements in MRI are only a proxy of their true dimensions, as the boundaries of their representation are consistently overestimated. The success in the use of the Frangi filter relies on a careful tuning of several parameters. Alpha= 0.5, beta= 0.5 and c= 500 yielded the best results. RORPO does not have these requirements and allows detecting smaller cylinders in their entirety more consistently in the absence of noise and confounding artefacts. The Frangi filter seems to be best suited for voxel sizes equal or larger than 0.4 mm-isotropic and cylinders larger than 1 mm diameter and 2 mm length. 'PVS' orientation did not affect measurements in data with isotropic voxels. COMPARISON WITH EXISTENT METHODS: Does not apply. CONCLUSIONS: The in-silico and physical phantoms presented are useful for establishing the validity of quantification methods of tubular small structures.

Keywords

MRI phantom, Perivascular spaces, Virchow-Robin spaces, Journal Article

Citation

Duarte Coello, R, Valdés Hernández, M D C, Zwanenburg, J J M, van der Velden, M, Kuijf, H J, De Luca, A, Moyano, J B, Ballerini, L, Chappell, F M, Brown, R, Jan Biessels, G & Wardlaw, J M 2024, 'Detectability and accuracy of computational measurements of in-silico and physical representations of enlarged perivascular spaces from magnetic resonance images', Journal of Neuroscience Methods, vol. 403, 110039. https://doi.org/10.1016/j.jneumeth.2023.110039