Biomechanics of Failed Pulmonary Autografts Compared With Normal Pulmonary Roots

Publication date

2016-12-01

Authors

Mookhoek, Aart
Krishnan, Kapil
Chitsaz, Sam
Kuang, Heide
Ge, Liang
Schoof, Paul H.ISNI 000000036926236X
Bogers, Ad J J C
Takkenberg, Johanna J M
Tseng, Elaine E.

Editors

Advisors

Supervisors

Document Type

Article

Collections

License

Abstract

Background Progressive dilatation of pulmonary autografts after the Ross operation may reflect inadequate remodeling of the native pulmonary root to adapt to systemic circulation. Understanding the biomechanics of autograft root dilatation may aid designing strategies to prevent dilatation. We have previously characterized normal human pulmonary root material properties; however, the mechanical properties of failed autografts are unknown. In this study, failed autograft roots explanted during reoperation were acquired, and their material properties were determined. Methods Failed pulmonary autograft specimens were obtained from patients undergoing reoperation after the Ross operation. Fresh human native pulmonary roots were obtained from the transplant donor network as controls. Biaxial stretch testing was performed to determine tissue mechanical properties. Tissue stiffness was determined at patient-specific physiologic stresses at pulmonary pressures. Results Nonlinear stress-strain response was present in both failed autografts and normal pulmonary roots. Explanted pulmonary autografts were less stiff than were their native pulmonary root counterparts at 8 mm Hg (134 ± 42 vs 175 ± 49 kPa, respectively) (p = 0.086) and 25 mm Hg (369 ± 105 vs 919 ± 353 kPa, respectively) (p = 0.006). Autograft wall stiffness at both 8 and 25 mm Hg was not correlated with age at the Ross procedure (p = 0.898 and p = 0.813, respectively) or with time in the systemic circulation (p = 0.609 and p = 0.702, respectively). Conclusions Failed pulmonary autografts retained nonlinear response to mechanical loading typical of healthy human arterial tissue. Remodeling increased wall thickness but decreased wall stiffness in failed autografts. Increased compliance may explain progressive autograft root dilatation in autograft failures.

Keywords

Surgery, Pulmonary and Respiratory Medicine, Cardiology and Cardiovascular Medicine, Journal Article

Citation

Mookhoek, A, Krishnan, K, Chitsaz, S, Kuang, H, Ge, L, Schoof, P H, Bogers, A J J C, Takkenberg, J J M & Tseng, E E 2016, 'Biomechanics of Failed Pulmonary Autografts Compared With Normal Pulmonary Roots', Annals of Thoracic Surgery, vol. 102, no. 6, pp. 1996-2002. https://doi.org/10.1016/j.athoracsur.2016.05.010