Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study

Publication date

2018

Authors

den Harder, Annemarie M.
Willemink, Martin J.
Jan van Doormaal, Pieter
Wessels, Frank J
Lock, M. T W TISNI 0000000388855697
Schilham, Arnold M RISNI 0000000391935778
Budde, Ricardo P JISNI 0000000392898112
Leiner, TimORCID 0000-0003-1885-5499ISNI 0000000390698205
de Jong, PimORCID 0000-0003-4840-6854ISNI 0000000395539334

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.

Keywords

Diagnostic, Imaging, Multidetector computed tomography, Radiation ionising, Sensitivity, Urolithiasis, Journal Article

Citation

den Harder, A M, Willemink, M J, van Doormaal, P J, Wessels, F J, Lock, M T W T, Schilham, A M R, Budde, R P J, Leiner, T & de Jong, P A 2018, 'Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction : A prospective intra-individual study', European Radiology, vol. 28, no. 1, pp. 143-150. https://doi.org/10.1007/s00330-017-4929-2