Abstract
Routine quality monitoring for fecal indicators after ozonation
at the river-lake waterworks Weesperkarspel of Amsterdam Water
Supply (AWS) show large variation in inactivation. The influence of the
high DOC in the water on the inactivation efficiency was investigated.
Results showed a higher inactivation of Clostridium perfringens in the AWS
water than in a water with low DOC at the same CT conditions. The contribution
of the gas feed chamber to the overall inactivation of C. perfringens
was high in the AWS water and was reduced after DOC reduction with
GAC. This result may alter the current CT concept of the process. Further
research will be focused on the ozone dosage strategy and control related
to the required CT for inactivation and the production of by-products.
Keywords