Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs

Publication date

2021-01-01

Authors

Hulsman, Alma H.
Breur, Johannes M.P.J.ISNI 0000000395622111
Szatmári, Viktor

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background: Minimally invasive transcatheter occlusion using Amplatz canine duct occluder (ACDO) is the treatment of choice for dogs with left-to-right shunting patent ductus arteriosus (PDA). However, in small dogs the femoral artery diameter is often too small to accommodate the guiding catheter required for ACDO deployment. Objective: Describe the effectiveness of transarterial implantation of Amplatzer Vascular Plug 4 (AVP-4), the only self-expandable nitinol mesh occlusion device which can be implanted through a 4 French diagnostic catheter, in small dogs with left-to-right shunting PDA. Animals: Seven client-owned dogs. Methods: Descriptive case series. Dogs with hemodynamically relevant left-to-right shunting PDA and a femoral artery diameter less than 2.0 mm measured preoperatively with ultrasonography were prospectively enrolled. Results: Angiography after releasing the device showed complete immediate PDA closure in 5 dogs, where the manufacturers' recommendation were strictly followed (30%-50% device oversizing of the ductal ampulla's diameter). Trivial residual flow on angiography in the 6th dog, whose device was slightly undersized, had resolved on echocardiography within 2 hours after placement. Marked device undersizing in the 7th dog resulted in severe residual shunting, which necessitated the addition of a coil. In this dog, the AVP-4 embolized into the pulmonary artery within 2 weeks after placement. Conclusions and Clinical Importance: Transarterial implantation of AVP-4 is a safe, effective and technically easy procedure for PDA occlusion in small dogs and offers a valuable alternative to coil implantation. Accurate PDA measurement and device sizing is essential to prevent residual shunting, inadvertent device embolization, and protrusion of the device into the aorta.

Keywords

Amplatz, coil, congenital, heart, Cardiac Catheterization/veterinary, Echocardiography, Angiography/veterinary, Ductus Arteriosus, Patent/diagnostic imaging, Treatment Outcome, Dog Diseases/diagnostic imaging, Pulmonary Artery, Animals, Dogs, General Veterinary, Journal Article

Citation

Hulsman, A H, Breur, J M P J & Szatmári, V 2021, 'Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs', Journal of Veterinary Internal Medicine, vol. 35, no. 1, pp. 98-106. https://doi.org/10.1111/jvim.15966