Outcome of patients supported with the HeartMate 3 after extracorporeal life support: On behalf of the Durable Mechanical Circulatory Support After Extracorporeal Life Support Study Group
Publication date
2024-08
Authors
Saeed, Diyar
Stark, Christoffer
Otto, Wolfgang
Loforte, Antonio
Zimpfer, Daniel
Bernhardt, Alexander M.
Potapov, Evgenij
Morshius, Michiel
Schibilsky, David
Albert, Alexander
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
No license information available
Abstract
Objectives: The Durable Mechanical Circulatory Support System After Extracorporeal Life Support registry is a multicenter registry of patients who were bridged from extracorporeal life support to a durable mechanical circulatory support system. Although numerous studies have highlighted the favorable outcomes after implantation of the HeartMate 3 (Abbott), the objective of our study is to examine the outcomes of patients who received HeartMate 3 support after extracorporeal life support. Methods: Data of patients undergoing HeartMate 3 implantation from January 2016 to April 2022 at 14 centers were collected and evaluated. Inclusion criteria were patients with extracorporeal life support before HeartMate 3 implantation. The outcome was reported and compared with patients receiving other types of pumps. Results: A total of 337 patients were bridged to durable mechanical circulatory support system after extracorporeal life support in the study period. Of those patients, 140 were supported with the HeartMate 3. The other types of pumps included 170 HeartWare HVADs (Medtronic) (86%), 14 HeartMate II devices (7%), and 13 (7%) other pumps (7%). Major postoperative complications included right heart failure requiring temporary right ventricular assist device in 60 patients (47%). Significantly lower postoperative stroke (16% vs 28%, P = .01) and pump thrombosis (3% vs 8%, P = .02) rates were observed in the patients receiving the HeartMate 3. The 30-day, 1-year, and 3-year survivals in patients receiving the HeartMate 3 were 87%, 73%, and 65%, respectively. Conclusions: In this critically ill patient population, the survivals of patients who were transitioned to the HeartMate 3 are deemed acceptable and superior to those observed when extracorporeal life support was bridged to other types of durable mechanical circulatory support systems.
Keywords
ECLS, ECMO, HeartMate 3, MCS, outcome, Taverne, Surgery, Pulmonary and Respiratory Medicine, Cardiology and Cardiovascular Medicine
Citation
Saeed, D, Stark, C, Otto, W, Loforte, A, Zimpfer, D, Bernhardt, A M, Potapov, E, Morshius, M, Schibilsky, D, Albert, A, Raweh, A, Riebandt, J, Pappalardo, F, Attisani, M, Rinaldi, M, Haneya, A, Huenges, K, Ramjankhan, F, Jorde, U P, Lewin, D, Jawad, K, Aubin, H, Ayala, R, Reichenspurner, H, Lichtenberg, A, Borger, M & Gummert, J 2024, 'Outcome of patients supported with the HeartMate 3 after extracorporeal life support : On behalf of the Durable Mechanical Circulatory Support After Extracorporeal Life Support Study Group', Journal of Thoracic and Cardiovascular Surgery, vol. 168, no. 2, pp. 569-578.e2. https://doi.org/10.1016/j.jtcvs.2023.08.048