Impact of thoracic endovascular aortic repair on radial strain in an ex vivo porcine model

Publication date

2017-04-01

Authors

Nauta, Foeke J.H.
de Beaufort, Hector W.
Conti, Michele
Marconi, Stefania
Kamman, Arnoud V.
Ferrara, Anna
van Herwaarden, Joost A.ORCID 0000-0003-1165-5179ISNI 0000000393686613
Moll, F. L.ISNI 0000000389761131
Auricchio, Ferdinando
Trimarchi, Santi

Editors

Advisors

Supervisors

Document Type

Article

Collections

License

Abstract

OBJECTIVES: To quantify the impact of thoracic endovascular aortic repair (TEVAR) on radial aortic strain with the aim of elucidating stent-graft-induced stiffening and complications. METHODS: Twenty fresh thoracic porcine aortas were connected to a mock circulatory loop driven by a centrifugal flow pump. A highdefinition camera captured diameters at five different pressure levels (100, 120, 140, 160, and 180 mmHg), before and after TEVAR. Three oversizing groups were created: 0-9% (n = 7), 10-19% (n = 6), and 20-29% (n = 6). Radial strain (or deformation) derived from diameter amplitude divided by baseline diameter at 100 mmHg. Uniaxial tensile testing evaluated Young's moduli of the specimens. RESULTS: Radial strain was reduced after TEVAR within the stented segment by 49.4 ± 24.0% (P < 0.001). As result, a strain mismatch was observed between the stented segment and the proximal non-stented segment (7.0 ± 2.5% vs 11.8 ± 3.9%, P < 0.001), whereas the distal non-stented segment was unaffected (P = 0.99). Stent-graft oversizing did not significantly affect the amount of strain reduction (P = 0.30). Tensile testing showed that the thoracic aortas tended to be more elastic proximally than distally (P = 0.11). CONCLUSIONS: TEVAR stiffened the thoracic aorta by 2-fold. Such segmental stiffening may diminish the Windkessel function considerably and might be associated with TEVAR-related complications, including stent-graft-induced dissection and aneurysmal dilatation. These data may have implications for future stent-graft design, in particular for TEVAR of the highly compliant proximal thoracic aorta.

Keywords

Aortic strain, Stent-graft, TEVAR, Thoracic aorta, Uniaxial tensile testing, Surgery, Pulmonary and Respiratory Medicine, Cardiology and Cardiovascular Medicine, Journal Article

Citation

Nauta, F J H, de Beaufort, H W L, Conti, M, Marconi, S, Kamman, A V, Ferrara, A, van Herwaarden, J A, Moll, F L, Auricchio, F & Trimarchi, S 2017, 'Impact of thoracic endovascular aortic repair on radial strain in an ex vivo porcine model', European Journal of Cardio-thoracic Surgery, vol. 51, no. 4, ezw369, pp. 783-789. https://doi.org/10.1093/ejcts/ezw393