Detection of Ischemic ST-Segment Changes Using a Novel Handheld ECG Device in a Porcine Model

Publication date

2023-07

Authors

de Vries, Nynke M.
Zepeda-Echavarria, Alejandra
van de Leur, Rutger
Loen, Vera
Vos, M AISNI 0000000395825015
Boonstra, Machteld J
Wildbergh, Thierry X.
Jaspers, Joris E.N.
van der Zee, Rien
Slump, Cornelis H.

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Background: Portable, smartphone-sized electrocardiography (ECG) has the potential to reduce time to treatment for patients suffering acute cardiac ischemia, thereby lowering the morbidity and mortality. In the UMC Utrecht, a portable, smartphone-sized, multi-lead precordial ECG recording device (miniECG 1.0, UMC Utrecht) was developed. Objectives: The purpose of this study was to investigate the ability of the miniECG to capture ischemic ECG changes in a porcine coronary occlusion model. Methods: In 8 animals, antero-septal myocardial infarction was induced by 75-minute occlusion of the left anterior descending artery, after the first or second diagonal. MiniECG and 12-lead ECG recordings were acquired simultaneously before, during and after coronary artery occlusion and ST-segment deviation was evaluated. Results: During the complete occlusion and reperfusion period, miniECG showed large ST-segment deviation in comparison to 12-lead ECG. MiniECG ST-segment deviation was observed within 1 minute for most animals. The miniECG was positive for ischemia (ie, ST-segment deviation ≥1 mm) for 99.7% (Q1-Q3: 99.6%-99.9%) of the occlusion time, while the 12-lead was only positive for 79.8% (Q1-Q3: 81.1%-98.7%) of the time (P = 0.018). ST-segment deviation reached maxima of 10.5 mm [95% CI: 6.5-14.5 mm] vs 5.0 mm [95% CI: 2.0-8.0 mm] for the miniECG vs 12-lead ECG, respectively. Conclusions: MiniECG ST-segment deviation was observed early and was of large magnitude during 75 minutes of porcine transmural antero-septal infarction. The miniECG was positive for ischemia for the complete occlusion period. These findings demonstrate the potential of the miniECG in the detection of cardiac ischemia. Although clinical research is required, data suggests that the miniECG is a promising tool for the detection of cardiac ischemia.

Keywords

cardiac ischemia, electrocardiography, portable, STEMI, translational research, Cardiology and Cardiovascular Medicine, Dentistry (miscellaneous)

Citation

de Vries, N M, Zepeda-Echavarria, A, van de Leur, R R, Loen, V, Vos, M A, Boonstra, M J, Wildbergh, T X, Jaspers, J E N, van der Zee, R, Slump, C H, Doevendans, P A & van Es, R 2023, 'Detection of Ischemic ST-Segment Changes Using a Novel Handheld ECG Device in a Porcine Model', JACC: Advances, vol. 2, no. 5, 100410. https://doi.org/10.1016/j.jacadv.2023.100410