Immunoassay for quantification of antigen-specific IgG fucosylation
Files
Publication date
2022-07
Authors
Šuštić, Tonći
Van Coillie, Julie
Larsen, Mads Delbo
Derksen, Ninotska I L
Szittner, Zoltan
Nouta, Jan
Wang, Wenjun
Damelang, Timon
Rebergen, Ianthe
Linty, Federica
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
cc_by_nc_nd
Abstract
BACKGROUND: Immunoglobulin G (IgG) antibodies serve a crucial immuno-protective function mediated by IgG Fc receptors (FcγR). Absence of fucose on the highly conserved N-linked glycan in the IgG Fc domain strongly enhances IgG binding and activation of myeloid and natural killer (NK) cell FcγRs. Although afucosylated IgG can provide increased protection (malaria and HIV), it also boosts immunopathologies in alloimmune diseases, COVID-19 and dengue fever. Quantifying IgG fucosylation currently requires sophisticated methods such as liquid chromatography-mass spectrometry (LC-MS) and extensive analytical skills reserved to highly specialized laboratories. METHODS: Here, we introduce the Fucose-sensitive Enzyme-linked immunosorbent assay (ELISA) for Antigen-Specific IgG (FEASI), an immunoassay capable of simultaneously quantitating and qualitatively determining IgG responses. FEASI is a two-tier immunoassay; the first assay is used to quantify antigen-specific IgG (IgG ELISA), while the second gives FcγRIIIa binding-dependent readout which is highly sensitive to both the IgG quantity and the IgG Fc fucosylation (FcγR-IgG ELISA). FINDINGS: IgG Fc fucosylation levels, independently determined by LC-MS and FEASI, in COVID-19 responses to the spike (S) antigen, correlated very strongly by simple linear regression (R2=0.93, p < 0.0001). The FEASI method was then used to quantify IgG levels and fucosylation in COVID-19 convalescent plasma which was independently validated by LC-MS. INTERPRETATION: FEASI can be reliably implemented to measure relative and absolute IgG Fc fucosylation and quantify binding of antigen-specific IgG to FcγR in a high-throughput manner accessible to all diagnostic and research laboratories. FUNDING: This work was funded by the Stichting Sanquin Bloedvoorziening (PPOC 19-08 and SQI00041) and ZonMW 10430 01 201 0021.
Keywords
COVID-19, Anti-spike IgG, IgG glycosylation, Fucosylation, SDG 3 - Good Health and Well-being
Citation
Šuštić, T, Van Coillie, J, Larsen, M D, Derksen, N I L, Szittner, Z, Nouta, J, Wang, W, Damelang, T, Rebergen, I, Linty, F, Visser, R, Mok, J Y, Geerdes, D M, van Esch, W J E, de Taeye, S W, van Gils, M J, van de Watering, L, van der Schoot, C E, Wuhrer, M, Rispens, T & Vidarsson, G 2022, 'Immunoassay for quantification of antigen-specific IgG fucosylation', EBioMedicine, vol. 81, 104109. https://doi.org/10.1016/j.ebiom.2022.104109