Screening of Drug-Transporter Interactions in a 3D Microfluidic Renal Proximal Tubule on a Chip

Publication date

2018-07-26

Authors

Vriend, Jelle
Nieskens, Tom T G
Vormann, Marianne K
van den Berge, Bartholomeus T
van den Heuvel, Angelique
Russel, Frans G M
Suter-Dick, Laura
Lanz, Henriëtte L
Vulto, Paul
Masereeuw, RosalindeORCID 0000-0002-1560-1074ISNI 0000000369326917

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

Abstract

Drug-transporter interactions could impact renal drug clearance and should ideally be detected in early stages of drug development to avoid toxicity-related withdrawals in later stages. This requires reliable and robust assays for which current high-throughput screenings have, however, poor predictability. Kidney-on-a-chip platforms have the potential to improve predictability, but often lack compatibility with high-content detection platforms. Here, we combined conditionally immortalized proximal tubule epithelial cells overexpressing organic anion transporter 1 (ciPTEC-OAT1) with the microfluidic titer plate OrganoPlate to develop a screenings assay for renal drug-transporter interactions. In this platform, apical localization of F-actin and intracellular tight-junction protein zonula occludens-1 (ZO-1) indicated appropriate cell polarization. Gene expression levels of the drug transporters organic anion transporter 1 (OAT1; SLC22A6), organic cation transporter 2 (OCT2; SLC22A2), P-glycoprotein (P-gp; ABCB1), and multidrug resistance-associated protein 2 and 4 (MRP2/4; ABCC2/4) were similar levels to 2D static cultures. Functionality of the efflux transporters P-gp and MRP2/4 was studied as proof-of-concept for 3D assays using calcein-AM and 5-chloromethylfluorescein-diacetate (CMFDA), respectively. Confocal imaging demonstrated a 4.4 ± 0.2-fold increase in calcein accumulation upon P-gp inhibition using PSC833. For MRP2/4, a 3.0 ± 0.2-fold increased accumulation of glutathione-methylfluorescein (GS-MF) was observed upon inhibition with a combination of PSC833, MK571, and KO143. Semi-quantitative image processing methods for P-gp and MRP2/4 was demonstrated with corresponding Z'-factors of 0.1 ± 0.3 and 0.4 ± 0.1, respectively. In conclusion, we demonstrate a 3D microfluidic PTEC model valuable for screening of drug-transporter interactions that further allows multiplexing of endpoint read-outs for drug-transporter interactions and toxicity.

Keywords

Drug-transporter interaction, Nephrotoxicity, Efflux transport, Microfluidics, Drug screening

Citation

Vriend, J, Nieskens, T T G, Vormann, M K, van den Berge, B T, van den Heuvel, A, Russel, F G M, Suter-Dick, L, Lanz, H L, Vulto, P, Masereeuw, R & Wilmer, M J 2018, 'Screening of Drug-Transporter Interactions in a 3D Microfluidic Renal Proximal Tubule on a Chip', The AAPS journal, vol. 20, no. 5, 87. https://doi.org/10.1208/s12248-018-0247-0