Lung transplant airway complications treated with biodegradable airway stents: The Dutch multi-center experience

Publication date

2024-03

Authors

van Pel, Roel
Gan, Tji
Daniels, Johannes M A
Ruigrok, G. A.
Hellemons, Merel E
Klooster, Karin
Slebos, Dirk-Jan

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

INTRODUCTION: Treatment of post lung-transplant airway complications is challenging, and treatment with conventional airway stents is associated with adverse events. More recently, biodegradable airway stents (BDS) have been introduced and may be used to reduce these adverse events. In this study we explore the feasibility of treatment with BDS post lung transplant. METHODS: All patients treated with BDS in The Netherlands were included in this retrospective multicenter study. Feasibility, life span of the stent, occurrence of adverse events, and evolution of lung function were evaluated. RESULTS: Twelve patients (six malacia and six stenosis) received a total of 57 BDS, ranging from 1 to 10 BDS per patient. Six patients had been pretreated with conventional airway stents. Median stent life span was 112 days (range 66-202). No adverse events occurred during stent placement. In 5 out of 57 stent placements, a single additional bronchoscopy was necessary because of mucus accumulation (n = 4) or excessive granulation tissue (n = 1). All stent naïve patients became airway stent independent after treatment; all patients pretreated with conventional airway stents were still airway stent dependent at the end of follow up. CONCLUSION: Treatment with BDS is safe and feasible. Adverse events were mild and easily treatable. All patients with initial treatment with BDS were airway stent independent at the end of follow up with a median treatment of 4 BDS.

Keywords

Bronchoscopy, Constriction, Pathologic/etiology, Humans, Lung Transplantation/adverse effects, Postoperative Complications/etiology, Stents/adverse effects, Treatment Outcome, Multicenter Study, Journal Article

Citation

van Pel, R, Gan, T, Daniels, J M A, Ruigrok, D, Hellemons, M E, Klooster, K & Slebos, D-J 2024, 'Lung transplant airway complications treated with biodegradable airway stents : The Dutch multi-center experience', Clinical transplantation, vol. 38, no. 3, e15289, pp. 1-6. https://doi.org/10.1111/ctr.15289