Deuterium body array for the simultaneous measurement of hepatic and renal glucose metabolism and gastric emptying with dynamic 3D deuterium metabolic imaging at 7T

Publication date

2023-08

Authors

Gursan, Ayhan
Hendriks, A.D.
Welting, Dimitri
de Jong, Pim AORCID 0000-0003-4840-6854ISNI 0000000395539334
Klomp, Dennis W.J.ORCID 0000-0002-5884-5386ISNI 0000000396514008
Prompers, Jeanine J.ORCID 0000-0002-4756-4474

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Deuterium metabolic imaging (DMI) is a novel noninvasive method to assess tissue metabolism and organ (patho)physiology in vivo using deuterated substrates, such as [6,6'- 2 H 2 ]-glucose. The liver and kidneys play a central role in whole-body glucose homeostasis, and in type 2 diabetes, both hepatic and renal glucose metabolism are dysregulated. Diabetes is also associated with gastric emptying abnormalities. In this study, we developed a four-channel 2 H transmit/receive body array coil for DMI in the human abdomen at 7 T and assessed its performance. In addition, the feasibility of simultaneously measuring gastric emptying, and hepatic and renal glucose uptake and metabolism with dynamic 3D DMI upon administration of deuterated glucose, was investigated. Simulated and measured B 1 + patterns were in good agreement. The intrasession variability of the natural abundance deuterated water signal in the liver and right kidney, measured in nine healthy volunteers, was 5.6% ± 0.9% and 4.9% ± 0.7%, respectively. Dynamic 3D DMI scans with oral administration of [6,6'- 2 H 2 ]-glucose showed similar kinetics of deuterated glucose appearance and disappearance in the liver and kidney. The measured gastric emptying half time was 80 ± 10 min, which is in good agreement with scintigraphy measurements. In conclusion, DMI with oral administration of [6,6'- 2 H 2 ]-glucose enables simultaneous assessment of gastric emptying and liver and kidney glucose uptake and metabolism. When applied in patients with diabetes, this approach may advance our understanding of the interplay between disturbances in liver and kidney glucose uptake and metabolism and gastric emptying, at a detail that cannot be achieved by any other method.

Keywords

deuterium metabolic imaging, gastric emptying, glucose metabolism, kidney, liver, Molecular Medicine, Radiology Nuclear Medicine and imaging, Spectroscopy, Journal Article

Citation

Gursan, A, Hendriks, A D, Welting, D, de Jong, P A, Klomp, D W J & Prompers, J J 2023, 'Deuterium body array for the simultaneous measurement of hepatic and renal glucose metabolism and gastric emptying with dynamic 3D deuterium metabolic imaging at 7T', NMR in Biomedicine, vol. 36, no. 8, e4926, pp. 1-14. https://doi.org/10.1002/nbm.4926