Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality

Publication date

2015-10

Authors

Timmers, Janine
ten Voorde, Marloes
van Engen, Ruben E.
van Landsveld-Verhoeven, Cary
Pijnappel, RuudORCID 0000-0002-6912-9414ISNI 0000000393536711
Droogh-de Greve, Kitty
den Heeten, Gerard J.
Broeders, Mireille J. M.

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Purpose: To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. Methods: 184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image taken with positioning sheets. 5 cases were excluded (missing data). Pain was scored using the Numeric Rating Scale. Radiation dose was estimated using the Dance model and projected breast area using computer software. Two radiologists and two radiographers assessed image quality. Results: With positioning sheets significantly more pectoral muscle, lateral and medial breast tissue was projected (CC-views) and more and deeper depicted pectoral muscle (MLO-views). In contrast, visibility of white and darker areas was better on images without positioning sheets, radiologists were therefore better able to detect abnormalities (MLO-views). Women experienced more pain with positioning sheets (MLO-views only, mean difference NRS 0.98; SD 1.71; p = 0,00). Conclusion: Mammograms with positioning sheets showed more breast tissue. Increased breast thickness after compression with sheets resulted in less visibility of white and darker areas and thus reduced detection of abnormalities. Also, women experienced more pain (MLO-views) due to the sheet material. A practical consideration is the fact that more subcutaneous fat tissue and skin are being pulled forward leading to folds in the nipple area. On balance, improvement to the current design is required before implementation in screening practice can be considered. (C) 2015 Elsevier Ireland Ltd. All rights reserved.

Keywords

Mammography, Performance, Breast neoplasms, Early detection of cancer, Radiographic image enhancement, Taverne, Comparative Study, Journal Article

Citation

Timmers, J, ten Voorde, M, van Engen, R E, van Landsveld-Verhoeven, C, Pijnappel, R, Droogh-de Greve, K, den Heeten, G J & Broeders, M J M 2015, 'Mammography with and without radiolucent positioning sheets : Comparison of projected breast area, pain experience, radiation dose and technical image quality', European Journal of Radiology, vol. 84, no. 10, pp. 1903-1909. https://doi.org/10.1016/j.ejrad.2015.07.005