T2-prepared velocity selective labelling: A novel idea for full-brain mapping of oxygen saturation

Publication date

2016-06-09

Authors

Alderliesten, ThomasISNI 0000000390456273
De Vis, J B
Lemmers, Petra M AISNI 0000000390732100
Van Bel, FrankISNI 000000038971030X
Benders, Manon J.N.L.ISNI 0000000388026661
Hendrikse, JeroenISNI 0000000390964171
Petersen, E T

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

BACKGROUND AND AIM: Disturbances in cerebral oxygenation saturation (SO2) have been linked to adverse outcome in adults, children, and neonates. In intensive care, the cerebral SO2 is increasingly being monitored by Near-InfraRed Spectroscopy (NIRS). Unfortunately NIRS has a limited penetration depth. The "modified T2-prepared Blood Imaging of Oxygen Saturation" (T2-BIOS) MR sequence provides a step towards full brain SO2 measurement. MATERIALS AND METHODS: Tissue SO2, and venous SO2 (SvO2) were obtained simultaneously by T2-BIOS during a respiratory challenge in ten healthy volunteers. These two measures were compared to SO2 that was obtained by a single probe MR-compatible NIRS setup, and to cerebral blood flow and venous SO2 that were obtained by arterial spin labelling and T2-TRIR, respectively. RESULTS: SO2-T2-BIOS and SO2-NIRS had a mean bias of -4.0% (95% CI -21.3% to 13.3%). SvO2-T2-BIOS correlated with SO2-NIRS (R(2)=0.41, p=0.002) and SvO2-T2-TRIR (R(2)=0.87, p=0.002). In addition, SO2-NIRS correlated with SvO2-T2-TRIR (R(2)=0.85, p=0.003) Frontal cerebral blood flow correlated with SO2-T2-BIOS (R(2)=0.21, p=0.04), but was not significant in relation to SO2-NIRS. DISCUSSION/CONCLUSION: Full brain SO2 assessment by any technique may help validating NIRS and may prove useful in guiding the clinical management of patient populations with cerebral injury following hypoxic-ischaemic events. The agreement between NIRS and T2-BIOS provides confidence in measuring cerebral SO2 by either technique. As it stands now, the T2-BIOS represents a novel idea and future work will focus on improvements to make it a reliable tool for SO2 assessment.

Keywords

Near-Infrared Spectroscopy;, Taverne, Journal Article

Citation

Alderliesten, T, De Vis, J B, Lemmers, P M A, van Bel, F, Benders, M J N L, Hendrikse, J & Petersen, E T 2016, 'T2-prepared velocity selective labelling : A novel idea for full-brain mapping of oxygen saturation', NeuroImage, vol. 139, pp. 65-73. https://doi.org/10.1016/j.neuroimage.2016.06.012