Diagnostic accuracy of point-of-care ultrasound for evaluation of early blood-induced joint changes: Comparison with MRI

Publication date

2018-11-01

Authors

Foppen, WouterORCID 0000-0003-4970-8555
van der Schaaf, Irene C.ISNI 0000000390429582
Beek, Frederik J AISNI 0000000388950176
Mali, WPTMISNI 0000000392849126
Fischer, KORCID 0000-0001-7126-6613

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc

Abstract

INTRODUCTION: Recurrent joint bleeding is the hallmark of haemophilia. Synovial hypertrophy observed with Magnetic Resonance Imaging (MRI) is associated with an increased risk of future joint bleeding. AIM: The aim of this study was to investigate whether point-of-care ultrasound (POC-US) is an accurate alternative for MRI for the detection of early joint changes. METHODS: In this single centre diagnostic accuracy study, bilateral knees and ankles of haemophilia patients with no or minimal arthropathy on X-rays were scanned using POC-US and 3 Tesla MRI. POC-US was performed by 1 medical doctor, blinded for MRI, according to the "Haemophilia Early Arthropathy Detection with Ultrasound" (HEAD-US) protocol. MRIs were independently scored by 2 radiologists, blinded for clinical data and ultrasound results. Diagnostic accuracy parameters were calculated with 95% confidence intervals (CI). RESULTS: Knees and ankles of 24 haemophilia patients (96 joints), aged 18-34, were studied. Synovial hypertrophy on MRI was observed in 20% of joints. POC-US for synovial tissue was correct (overall accuracy) in 97% (CI: 91-99) with a positive predictive value of 94% (CI: 73-100) and a negative predictive value of 97% (CI: 91-100). The overall accuracy of POC-US for cartilage abnormalities was 91% (CI: 83-96) and for bone surface irregularities 97% (CI: 91-99). CONCLUSION: POC-US could accurately assess synovial hypertrophy, bone surface irregularities and cartilage abnormalities in haemophilia patients with limited joint disease. As POC-US is an accurate and available alternative for MRI, it can be used for routine evaluation of early joint changes.

Keywords

arthropathy, haemarthrosis, MRI, Sensitivity, Specificity, Ultrasound, Humans, Joints/diagnostic imaging, Male, Young Adult, Hemarthrosis/diagnostic imaging, Magnetic Resonance Imaging, Point-of-Care Systems, Sensitivity and Specificity, Ultrasonography, Adult, Female, Genetics(clinical), Hematology, Journal Article, Comparative Study

Citation

Foppen, W, van der Schaaf, I C, Beek, F J A, Mali, W P T M & Fischer, K 2018, 'Diagnostic accuracy of point-of-care ultrasound for evaluation of early blood-induced joint changes : Comparison with MRI', Haemophilia, vol. 24, no. 6, pp. 971-979. https://doi.org/10.1111/hae.13524