Electrophysiological measurements that can explain and guide temporary accelerated pacing to avert (re)occurrence of torsade de pointes arrhythmias in the canine chronic atrioventricular block model

Publication date

2017-05-01

Authors

Wijers, Sofieke C.
Bossu, Alexandre
Dunnink, Albert
Beekman, Jet D.M.ISNI 0000000389505445
Varkevisser, Rosanne
Aranda Hernández, Alfonso
Meine, MathiasORCID 0000-0002-1102-2155ISNI 0000000369243476
Vos, Marc A.ISNI 0000000395825015

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

BACKGROUND: Pacing at higher rates is known to suppress torsade de pointes (TdP) arrhythmias. Nevertheless, exact application and mechanism need further clarification. In the anesthetized canine chronic atrioventricular block model, ventricular remodeling is responsible for a high and reproducible incidence of TdP upon a challenge with dofetilide. OBJECTIVE: We used this model to investigate by what mechanism accelerated pacing averts TdP and what repolarization parameter could be used to guide temporary accelerated pacing (TAP). METHODS: Ten dogs with repetitive TdP after administration of dofetilide when paced at 60 beats/min were selected. In a serial experiment, TAP was initiated at 100 beats/min after the first ectopic beat. Electrocardiogram and right and left ventricular (LV) monophasic action potential durations (MAPDs) were recorded. In a subset, vertical dispersion was determined with a duodecapolar catheter. Temporal dispersion was quantified as short-term variability (STV). Arrhythmias were quantified with the arrhythmia score. RESULTS: The increase in repolarization parameters observed after administration of dofetilide was counteracted by TAP (eg, LV MAPD from 381 ± 94 ms back to 310 ± 17 ms; P < .05). Temporal dispersion (STV LVMAPD) increased from 0.69 ± 0.37 to 2.59 ± 0.96 ms (P < .05) after administration of dofetilide and back to 1.15 ± 0.54 ms (P < .05) with TAP. This was accompanied by suppression of recurrent TdP in 7 of 10 dogs (P < .05) and a trend toward reduction in vertical (spatial) dispersion from 56 ± 25 to 31 ± 4 ms (P = .06). In those dogs, seconds after capture of TAP, almost all ectopy disappeared, causing a decrease in arrhythmia score from 21 ± 12 to 4 ± 3 (P < .05). CONCLUSION: TAP is effective in averting TdP by decreasing spatial and temporal measures of repolarization. Increase in temporal dispersion (STV) can guide TAP.

Keywords

Dispersion, Pacing, Prevention, Short-term variability, Torsade de pointes, Taverne, Cardiology and Cardiovascular Medicine, Physiology (medical), Journal Article

Citation

Wijers, S C, Bossu, A, Dunnink, A, Beekman, J D M, Varkevisser, R, Aranda Hernández, A, Meine, M & Vos, M A 2017, 'Electrophysiological measurements that can explain and guide temporary accelerated pacing to avert (re)occurrence of torsade de pointes arrhythmias in the canine chronic atrioventricular block model', Heart Rhythm, vol. 14, no. 5, pp. 749-756. https://doi.org/10.1016/j.hrthm.2017.02.007