Comparison of three remote radiolabelling methods for long-circulating liposomes

Publication date

2015-12-28

Authors

Van Der Geest, Tessa
Laverman, Peter
Gerrits, Danny
Franssen, Gerben M.
Metselaar, JosbertISNI 0000000394733565
Storm, GerritISNI 0000000042534976
Boerman, Otto C.

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

taverne

Abstract

Long-circulating liposomes (LCL) are often used as a drug carrier system to improve the therapeutic index of water-soluble drugs. To track these LCL in vivo, they can be radiolabelled with 111In-oxine. For this labellingmethod, generally DTPA is encapsulated in the aqueous phase of LCL (DTPA-LCL). Alternatively, LCL can be labelled with 111InCl3 after incorporation of DTPA-conjugated DSPE in the lipid bilayer (DTPA-DSPE LCL). Here, we compared the in vitro properties of DTPA-DSPE LCLwith those of DTPA LCL and empty LCL. Additionally, we compared the in vivo performance of DTPA-DSPE LCL with those of DTPA LCL in mice. DTPA LCL (88 nm) and empty LCL (84 nm) were labelled with 111In-oxine, and DTPA-DSPE LCL (83 nm) were labelled with 111InCl3. Labelling efficiency at increasing specific activity was determined. In vitro stability of 111In-labelled LCL was determined in human serum at 37 °C. The in vivo properties of 111In-labelled LCL were determined in mice with a Staphylococcus aureus infection in the thigh muscle. Image acquisition, blood sampling and biodistribution studies were performed 1, 4 (blood sampling only), 24, 48 and 72 h p.i. of 111In-labelled LCL. DTPA-DSPE LCL could be labelled efficiently at a much higher specific activity compared to DTPA LCL and empty LCL: >90% at 15 GBq/mmol, >90% at 150 MBq/mmol and 6065% at 150 MBq/mmol, respectively. 111In-labelled DTPA-DSPE LCL and DTPA LCL were stable in human serum, regarding label retention, for at least 48 h at 37 °C (>98% retention of the radiolabel). In contrast, only 68% radiolabel was retained in empty LCL after 48 h. In vivo targeting of 111In-DTPA-DSPE LCL to the abscess was comparable to targeting of 111In-DTPA LCL (3.5 ± 0.9%ID/g and 3.4 ± 0.9%ID/g abscess uptake respectively, 48 h p.i.). In conclusion, labelling of DTPA-DSPE LCL with 111InCl3 represents a robust, easy and fast procedurewhich is preferred over the more laborious conventional labelling of DTPA-LCL with 111In-oxine.

Keywords

DTPA-DSPE-PEG liposomes, DTPA-PEG liposomes, MicroSPECT/CT imaging, Staphylococcus aureus, Targeting, Taverne, Pharmaceutical Science

Citation

Van Der Geest, T, Laverman, P, Gerrits, D, Franssen, G M, Metselaar, J M, Storm, G & Boerman, O C 2015, 'Comparison of three remote radiolabelling methods for long-circulating liposomes', Journal of Controlled Release, vol. 220, pp. 239-244. https://doi.org/10.1016/j.jconrel.2015.10.043