Ex Vivo Pilot Study of Cardiac Magnetic Resonance Velocity Mapping for Quantification of Aortic Regurgitation in a Porcine Model in the Presence of a Transcatheter Heart Valve

Publication date

2019-08-15

Authors

Kooistra, Nynke H M
Nijhoff, Freek
Abawi, Masieh
Agostoni, PiefrancescoISNI 0000000388177910
Araya Roos, Daniël M
van Tuijl, Sjoerd
Blanken, Niels
Voskuil, MichielISNI 0000000392050007
Doevendans, PieterISNI 0000000110574516
Stella, Pieter R.ISNI 0000000393574363

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Accuracy of aortic regurgitation (AR) quantification by magnetic resonance (MR) imaging in the presence of a transcatheter heart valve (THV) remains to be established. We evaluated the accuracy of cardiac MR velocity mapping for quantification of antegrade flow (AF) and retrograde flow (RF) across a THV and the optimal slice position to use in cardiac MR imaging. In a systematic and fully controlled laboratory ex vivo setting, two THVs (Edwards SAPIEN XT, Medtronic CoreValve) were tested in a porcine model (n = 1) under steady flow conditions. Results showed a high level of accuracy and precision. For both THVs, AF was best measured at left ventricular outflow tract level, and RF at ascending aorta level. At these levels, MR had an excellent repeatability (ICC > 0.99), with a tendency to overestimate (4.6 ± 2.4% to 9.4 ± 7.0%). Quantification of AR by MR velocity mapping in the presence of a THV was accurate, precise, and repeatable in this pilot study, when corrected for the systematic error and when the best MR slice position was used. Confirmation of these results in future clinical studies would be a step forward in increasing the accuracy of the assessment of paravalvular AR severity.

Keywords

Cardiac magnetic resonance velocity mapping, Paravalvular aortic regurgitation, Quantification, Transcatheter heart valve, Taverne, Molecular Medicine, Genetics, Pharmaceutical Science, Cardiology and Cardiovascular Medicine, Genetics(clinical)

Citation

Kooistra, N H M, Nijhoff, F, Abawi, M, Agostoni, P, Araya Roos, D M, van Tuijl, S, Blanken, N, Voskuil, M, Doevendans, P A F M, Stella, P R & Leiner, T 2019, 'Ex Vivo Pilot Study of Cardiac Magnetic Resonance Velocity Mapping for Quantification of Aortic Regurgitation in a Porcine Model in the Presence of a Transcatheter Heart Valve', Journal of Cardiovascular Translational Research, vol. 12, no. 4, pp. 310-320. https://doi.org/10.1007/s12265-019-09878-1