Estimation of Respiratory Rate from Functional Near-Infrared Spectroscopy (fNIRS): A New Perspective on Respiratory Interference

Publication date

2022-12-14

Authors

Hakimi, Naser
Shahbakhti, Mohammad
Sappia, Sofia
Horschig, Jörn M.
Bronkhorst, Mathijs
Floor-Westerdijk, Marianne
Valenza, Gaetano
Dudink, JeroenISNI 0000000387693657
Colier, Willy N.J.M.

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

OBJECTIVE: Respiration is recognized as a systematic physiological interference in functional near-infrared spectroscopy (fNIRS). However, it remains unanswered as to whether it is possible to estimate the respiratory rate (RR) from such interference. Undoubtedly, RR estimation from fNIRS can provide complementary information that can be used alongside the cerebral activity analysis, e.g., sport studies. Thus, the objective of this paper is to propose a method for RR estimation from fNIRS. Our primary presumption is that changes in the baseline wander of oxygenated hemoglobin concentration (O2Hb) signal are related to RR. METHODS: fNIRS and respiratory signals were concurrently collected from subjects during controlled breathing tasks at a constant rate from 0.1 Hz to 0.4 Hz. Firstly, the signal quality index algorithm is employed to select the best O2Hb signal, and then a band-pass filter with cut-off frequencies from 0.05 to 2 Hz is used to remove very low- and high-frequency artifacts. Secondly, troughs of the filtered O2Hb signal are localized for synthesizing the baseline wander (S1) using cubic spline interpolation. Finally, the fast Fourier transform of the S1 signal is computed, and its dominant frequency is considered as RR. In this paper, two different datasets were employed, where the first one was used for the parameter adjustment of the proposed method, and the second one was solely used for testing. RESULTS: The low mean absolute error between the reference and estimated RRs for the first and second datasets (2.6 and 1.3 breaths per minute, respectively) indicates the feasibility of the proposed method for RR estimation from fNIRS. SIGNIFICANCE: This paper provides a novel view on the respiration interference as a source of complementary information in fNIRS.

Keywords

estimation, fNIRS, physiological interference, respiratory rate, signal quality index, Analytical Chemistry, Biotechnology, Biomedical Engineering, Instrumentation, Engineering (miscellaneous), Clinical Biochemistry, Journal Article

Citation

Hakimi, N, Shahbakhti, M, Sappia, S, Horschig, J M, Bronkhorst, M, Floor-Westerdijk, M, Valenza, G, Dudink, J & Colier, W N J M 2022, 'Estimation of Respiratory Rate from Functional Near-Infrared Spectroscopy (fNIRS) : A New Perspective on Respiratory Interference', Biosensors, vol. 12, no. 12, 1170. https://doi.org/10.3390/bios12121170