Abstract
AIMS: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3-6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients' medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients' health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. CONCLUSION: Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation.ClinicalTrials.gov Identifier: NCT01691586.
Keywords
Health status, Heart failure, Implantable cardioverter-defibrillator, Patient-reported outcomes, Remote monitoring, REMOTE-CIED, Taverne, Cardiology and Cardiovascular Medicine, Physiology (medical)
Citation
Versteeg, H, Timmermans, I, Widdershoven, J, Kimman, G J, Prevot, S, Rauwolf, T, Scholten, M F, Zitron, E, Mabo, P, Denollet, J, Pedersen, S S & Meine, M 2019, 'Effect of remote monitoring on patient-reported outcomes in European heart failure patients with an implantable cardioverter-defibrillator : primary results of the REMOTE-CIED randomized trial', Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, vol. 21, no. 9, pp. 1360-1368. https://doi.org/10.1093/europace/euz140