Radiofrequency localization of nonpalpable breast cancer in a multicentre prospective cohort study: feasibility, clinical acceptability, and safety

Publication date

2023-08

Authors

Christenhusz, Anke
Den Dekker, B.
Van Dalen, T.ISNI 0000000387114977
Jongen, Lisa
van der Schaaf, Margreet C
Alic, Lejla
Ten Haken, Bennie
Pijnappel, Ruud M.ORCID 0000-0002-6912-9414ISNI 0000000393536711
Dassen, Anneriet E

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

PURPOSE: In breast conserving surgery, accurate lesion localization is essential for obtaining adequate surgical margins. Preoperative wire localization (WL) and radioactive seed localization (RSL) are widely accepted methods to guide surgical excision of nonpalpable breast lesions but are limited by logistical challenges, migration issues, and legislative complexities. Radiofrequency identification (RFID) technology may offer a viable alternative. The purpose of this study was to evaluate the feasibility, clinical acceptability, and safety of RFID surgical guidance for localization of nonpalpable breast cancer. METHODS: In a prospective multicentre cohort study, the first 100 RFID localization procedures were included. The primary outcome was the percentage of clear resection margins and re-excision rate. Secondary outcomes included procedure details, user experience, learningcurve, and adverse events. RESULTS: Between April 2019 and May 2021, 100 women underwent RFID guided breast conserving surgery. Clear resection margins were obtained in 89 out of 96 included patients (92.7%), re-excision was indicated in three patients (3.1%). Radiologists reported difficulties with the placement of the RFID tag, partially related to the relatively large needle-applicator (12-gauge). This led to the premature termination of the study in the hospital using RSL as regular care. The radiologist experience was improved after a manufacturer modification of the needle-applicator. Surgical localization involved a low learning curve. Adverse events (n = 33) included dislocation of the marker during insertion (8%) and hematomas (9%). The majority of adverse events (85%) occurred using the first-generation needle-applicator. CONCLUSION: RFID technology is a potential alternative for non-radioactive and non-wire localization of nonpalpable breast lesions.

Keywords

Breast cancer, Breast conserving surgery, Primary lesion localization, Radiofrequency identification, RFID, Oncology, Cancer Research, Journal Article

Citation

Christenhusz, A, den Dekker, B M, van Dalen, T, Jongen, L, van der Schaaf, M C, Alic, L, Ten Haken, B, Pijnappel, R M & Dassen, A E 2023, 'Radiofrequency localization of nonpalpable breast cancer in a multicentre prospective cohort study : feasibility, clinical acceptability, and safety', Breast Cancer Research and Treatment, vol. 201, no. 1, pp. 67-75. https://doi.org/10.1007/s10549-023-07006-x