Psychometrics of Wearable Devices Measuring Physical Activity in Ambulant Children With Gait Abnormalities: A Systematic Review and Meta-analysis

Publication date

2024-12

Authors

van Moorsel, Huib
Engels, Barbara
Buczny, Jacek
Gorter, Jan WillemORCID 0000-0002-3012-2119
Arbour-Nicitopoulos, Kelly
Takken, TORCID 0000-0002-7737-118XISNI 0000000369069877
Engelbert, Raoul H.H.
Bloemen, Manon

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Objective: To evaluate psychometrics of wearable devices measuring physical activity (PA) in ambulant children with gait abnormalities due to neuromuscular conditions. Data Sources: We searched PubMed, Embase, PsycINFO, CINAHL, and SPORTDiscus in March 2023. Study Selection: We included studies if (1) participants were ambulatory children (2-19y) with gait abnormalities, (2) reliability and validity were analyzed, and (3) peer-reviewed studies in the English language and full-text were available. We excluded studies of children with primarily visual conditions, behavioral diagnoses, or primarily cognitive disability. We performed independent screening and inclusion, data extraction, assessment of the data, and grading of results with 2 researchers. Data Extraction: Our report follows Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We assessed methodological quality with Consensus-based Standards for the selection of health measurement instruments. We extracted data on reported reliability, measurement error, and validity. We performed meta-analyses for reliability and validity coefficient values. Data Synthesis: Of 6911 studies, we included 26 with 1064 participants for meta-analysis. Results showed that wearables measuring PA in children with abnormal gait have high to very high reliability (intraclass correlation coefficient [ICC]+, test-retest reliability=0.81; 95% confidence interval [CI], 0.74-0.89; I2=88.57%; ICC+, interdevice reliability=0.99; 95% CI, 0.98-0.99; I2=71.01%) and moderate to high validity in a standardized setting (r+, construct validity=0.63; 95% CI, 0.36-0.89; I2=99.97%; r+, criterion validity=0.68; 95% CI, 0.57-0.79; I2=98.70%; r+, criterion validity cutoff point based=0.69; 95% CI, 0.58-0.80; I2=87.02%). The methodological quality of all studies included in the meta-analysis was moderate. Conclusions: There was high to very high reliability and moderate to high validity for wearables measuring PA in children with abnormal gait, primarily due to neurological conditions. Clinicians should be aware that several moderating factors can influence an assessment.

Keywords

Accelerometry, Gait abnormality, Meta-analysis, Physical activity, Psychometric properties, Rehabilitation, Systematic review, Rehabilitation, Physical Therapy, Sports Therapy and Rehabilitation

Citation

van Moorsel, H, Engels, B, Buczny, J, Gorter, J W, Arbour-Nicitopoulos, K, Takken, T, Engelbert, R H H & Bloemen, M A T 2024, 'Psychometrics of Wearable Devices Measuring Physical Activity in Ambulant Children With Gait Abnormalities : A Systematic Review and Meta-analysis', Archives of rehabilitation research and clinical translation, vol. 6, no. 4, 100384. https://doi.org/10.1016/j.arrct.2024.100384