Errors in the method of line-reversal
Publication date
1967-12
Authors
Snelleman, W.
Editors
Advisors
Supervisors
DOI
Document Type
Article
Metadata
Show full item recordCollections
License
Abstract
It is shown that with a favourable experimental design the random error in the temperature measurement of hot gases with the method of line-reversal is of the order of 1 deg. K at about 2500°K. A number of Systematic errors, each of the order of 10 deg.K, are considered. Some applications of the method are discussed quantitatively and a procedure is indicated for the reversal measurement of gas temperature which are higher than the brightness temperature of the available background light source.