Energy performance of a 1.2 MWp photovoltaic system distributed over nine buildings at Utrecht University campus
Publication date
2017
Editors
Smets, A.
Taylor, N.
Helm, P.
Advisors
Supervisors
Document Type
Part of book
Metadata
Show full item recordCollections
License
Abstract
A distributed PV system comprising of eight subsystems on separate buildings totaling an installed capacity of 1.2 MWp has been realized at buildings of the Utrecht University campus Utrecht Science Park. A detailed design process was followed taking into account the presence of surrounding buildings. This has lead to a system with modules oriented South, West, East, and even North. Most of the modules are installed at a tilt of 10 degrees. A full year of monitoring results is presented here and shows that the system is performing well, with an average performance ratio of 0.825, thus delivering more than 1 million kWh annually.
Keywords
Education and Training, Large Grid-Connected PV Systems, PV System, Energy Performance, Design, SDG 7 - Affordable and Clean Energy
Citation
van Sark, W G J H M, de Waal, A C, Uithol, J, Dols, N, Houben, F, Kuepers, R, Sterrenburg, M, van Lith, B & Benjamin, F 2017, Energy performance of a 1.2 MWp photovoltaic system distributed over nine buildings at Utrecht University campus. in A Smets, N Taylor & P Helm (eds), Proceedings of the 33rd European Photovoltaic Solar Energy Conference. WIP-Renewable Energies, Munich, Germny, pp. 2284-2287. https://doi.org/10.4229/EUPVSEC20172017-6BV.1.31