Scoring haemophilic arthropathy on X-rays: improving inter- and intra-observer reliability and agreement using a consensus atlas

Publication date

2016-06

Authors

Foppen, WouterORCID 0000-0003-4970-8555
van der Schaaf, Irene CISNI 0000000390429582
Beek, Frederik J AISNI 0000000388950176
Verkooijen, Helena MORCID 0000-0001-9480-1623
Fischer, KathelijnORCID 0000-0001-7126-6613

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

OBJECTIVES: The radiological Pettersson score (PS) is widely applied for classification of arthropathy to evaluate costly haemophilia treatment. This study aims to assess and improve inter- and intra-observer reliability and agreement of the PS. METHODS: Two series of X-rays (bilateral elbows, knees, and ankles) of 10 haemophilia patients (120 joints) with haemophilic arthropathy were scored by three observers according to the PS (maximum score 13/joint). Subsequently, (dis-)agreement in scoring was discussed until consensus. Example images were collected in an atlas. Thereafter, second series of 120 joints were scored using the atlas. One observer rescored the second series after three months. Reliability was assessed by intraclass correlation coefficients (ICC), agreement by limits of agreement (LoA). RESULTS: Median Pettersson score at joint level (PSjoint) of affected joints was 6 (interquartile range 3-9). Using the consensus atlas, inter-observer reliability of the PSjoint improved significantly from 0.94 (95 % confidence interval (CI) 0.91-0.96) to 0.97 (CI 0.96-0.98). LoA improved from ±1.7 to ±1.1 for the PSjoint. Therefore, true differences in arthropathy were differences in the PSjoint of >2 points. Intra-observer reliability of the PSjoint was 0.98 (CI 0.97-0.98), intra-observer LoA were ±0.9 points. CONCLUSIONS: Reliability and agreement of the PS improved by using a consensus atlas. KEY POINTS: • Reliability of the Pettersson score significantly improved using the consensus atlas. • The presented consensus atlas improved the agreement among observers. • The consensus atlas could be recommended to obtain a reproducible Pettersson score.

Keywords

Haemophilia, Arthropathy, X-rays, Reliability, Agreement, Journal Article

Citation

Foppen, W, van der Schaaf, I C, Beek, F J A, Verkooijen, H M & Fischer, K 2016, 'Scoring haemophilic arthropathy on X-rays : improving inter- and intra-observer reliability and agreement using a consensus atlas', European Radiology, vol. 26, no. 6, pp. 1963-1970. https://doi.org/10.1007/s00330-015-4013-8