The Current State of Mock Circulatory Loop Applications in Aortic and Cardiovascular Research: A Scoping Review
Publication date
2026-01
Authors
Osinga, Felix E.N.
Hasami, Nesar A.
de Kort, Jasper F.
Maris, Emma Lena
Domanin, Maurizio
Schembri, Martina
Caimi, Alessandro
Conti, Michele
Hazenberg, Stijn
Auricchio, Ferdinando
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
cc_by
Abstract
Background: Mock circulatory loops (MCLs) are benchtop experimental platforms that reproduce key features of the human cardiovascular system, providing a safe, controlled, and reproducible environment for haemodynamic investigation. This scoping review aims to systematically map the current landscape of MCLs used for aortic simulation and identify major areas of application. Methods: A systematic search of PubMed, Scopus, and Web of Science identified original studies employing MCLs for aortic simulation. Eligible studies were categorized into predefined themes: (I) (bio)mechanical aortic characterization, (II) hemodynamics, (III) device testing, (IV) diagnostics, and (V) training. Data on MCL configurations, aortic models, and study objectives were synthesized narratively. Results: Eighty-four studies met the inclusion criteria. Twenty-five investigated aortic biomechanics, 23 hemodynamics, 22 device or product testing, 13 validated diagnostic imaging techniques, and one training application. Models included porcine (n = 22), human cadaveric (n = 7), canine (n = 1), ovine (n = 1), bovine (n = 1), and 3D-printed or molded aortic phantoms (n = 55). MCLs were employed to study parameters such as aortic stiffness, flow dynamics, dissection propagation, endoleaks, imaging accuracy, and device performance. Conclusions: This review provides a comprehensive overview of MCL applications in aortic research. MCLs represent a versatile pre-clinical platform for studying aortic pathophysiology and testing endovascular therapies under controlled conditions. Standardized reporting frameworks are now required to improve reproducibility and accelerate translation to patient-specific planning.
Keywords
aorta, aortic stiffness, endovascular aortic repair, mock circulatory loop, pulse wave velocity, TEVAR, Medicine (miscellaneous), General Biochemistry,Genetics and Molecular Biology
Citation
Osinga, F E N, Hasami, N A, de Kort, J F, Maris, E L, Domanin, M, Schembri, M, Caimi, A, Conti, M, Hazenberg, C E V B, Auricchio, F, de Bruin, J L, van Herwaarden, J A & Trimarchi, S 2026, 'The Current State of Mock Circulatory Loop Applications in Aortic and Cardiovascular Research : A Scoping Review', Biomedicines, vol. 14, no. 1, 28. https://doi.org/10.3390/biomedicines14010028