Metabolite cycled liver 1 H MRS on a 7 T parallel transmit system

Publication date

2020-08

Authors

Xavier, Aline
Arteaga de Castro, Catalina SISNI 0000000389791234
Andia, Marcelo E
Luijten, Peter R.ORCID 0000-0002-8040-8449ISNI 0000000397136870
Klomp, Dennis W.J.ORCID 0000-0002-5884-5386ISNI 0000000396514008
Fillmer, Ariane
Prompers, Jeanine J.ORCID 0000-0002-4756-4474

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

INTRODUCTION: Single-voxel 1 H MRS in body applications often suffers from respiratory and other motion induced phase and frequency shifts, which lead to incoherent averaging and hence to suboptimal results. METHODS: Here we show the application of metabolite cycling (MC) for liver STEAM-localized 1 H MRS on a 7 T parallel transmit system, using eight transmit-receive fractionated dipole antennas with 16 additional, integrated receive loops. MC-STEAM measurements were made in six healthy, lean subjects and compared with STEAM measurements using VAPOR water suppression. Measurements were performed during free breathing and during synchronized breathing, for which the subjects did breathe in between the MRS acquisitions. Both intra-session repeatability and inter-session reproducibility of liver lipid quantification with MC-STEAM and VAPOR-STEAM were determined. RESULTS: The preserved water signal in MC-STEAM allowed for robust phase and frequency correction of individual acquisitions before averaging, which resulted in in vivo liver spectra that were of equal quality when measurements were made with free breathing or synchronized breathing. Intra-session repeatability and inter-session reproducibility of liver lipid quantification were better for MC-STEAM than for VAPOR-STEAM. This may also be explained by the more robust phase and frequency correction of the individual MC-STEAM acquisitions as compared with the VAPOR-STEAM acquisitions, for which the low-signal-to-noise ratio lipid signals had to be used for the corrections. CONCLUSION: Non-water-suppressed MC-STEAM on a 7 T system with parallel transmit is a promising approach for 1 H MRS applications in the body that are affected by motion, such as in the liver, and yields better repeatability and reproducibility compared with water-suppressed measurements.

Keywords

7 T, MRS, lipid composition, lipids, liver, metabolite cycling, parallel transmit, ultra-high field, Molecular Medicine, Radiology Nuclear Medicine and imaging, Spectroscopy, Journal Article

Citation

Xavier, A, Arteaga de Castro, C, Andia, M E, Luijten, P R, Klomp, D W, Fillmer, A & Prompers, J J 2020, 'Metabolite cycled liver 1 H MRS on a 7 T parallel transmit system', NMR in Biomedicine, vol. 33, no. 8, e4343, pp. 1-14. https://doi.org/10.1002/nbm.4343