Results of endovascular aortic arch repair using the Relay Branch system
Files
Publication date
2021-09-01
Authors
Czerny, Martin
Berger, Tim
Kondov, Stoyan
Siepe, Matthias
Saint Lebes, Bertrand
Mokrane, Fatima
Rousseau, Herve
Lescan, Mario
Schlensak, Christian
Andic, Mateja
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
Objectives: Our goal was to evaluate results of endovascular aortic arch repair using the Relay Branch system. Methods: Forty-three patients with thoracic aortic pathology involving the aortic arch have been treated with the Relay Branch system (Terumo Aortic, Sunrise, FL, USA) in 10 centres. We assessed in-hospital mortality, neurological injury, treatment success according to current reporting standards and the need for secondary interventions. In addition, outcome was analysed according to the underlying pathology: non-dissective disease versus residual aortic dissection (RAD) (defined as remaining dissection after previous type A repair, chronic type B aortic dissections). Results: In-hospital mortality was 9% (0% in patients with RAD). Disabling stroke occurred in 7% (0% in patients with RAD); non-disabling stroke occurred in 19% (7% in patients with RAD). Early type IA and B endoleak formation occurred in 4%. Median follow-up was 16 ± 18 months. During the follow-up period, 23% of the patients died. Aortic-related deaths were low (3% in patients with RAD). Conclusions: The results of endovascular aortic arch repair using the Relay Branch system in a selected patient population with regard to technical success are good. In-hospital mortality is acceptable, the number of disabling strokes is low and technical success is high. Non-disabling stroke is a major concern, and every effort has to be taken to reduce this to a minimum. The best outcome is seen in patients with underlying RAD. Finally, more data are needed.
Keywords
Aortic arch, Endovascular aortic repair, Thoracic endovascular aortic repair, Taverne, Surgery, Pulmonary and Respiratory Medicine, Cardiology and Cardiovascular Medicine
Citation
Czerny, M, Berger, T, Kondov, S, Siepe, M, Saint Lebes, B, Mokrane, F, Rousseau, H, Lescan, M, Schlensak, C, Andic, M, Hazenberg, C, Bloemert-Tuin, T, Braithwaite, S, Van Herwaarden, J, Hyhlik-Dürr, A, Gosslau, Y, Pedro, L M, Amorim, P, Kuratani, T, Cheng, S, Heijmen, R, Van Der Weijde, E, Pleban, E, Szopiński, P & Rylski, B 2021, 'Results of endovascular aortic arch repair using the Relay Branch system', European Journal of Cardio-thoracic Surgery, vol. 60, no. 3, pp. 662-668. https://doi.org/10.1093/ejcts/ezab160