MRI-based inter- and intrafraction motion analysis of the pancreatic tail and spleen as preparation for adaptive MRI-guided radiotherapy in neuroblastoma

Publication date

2023-10-02

Authors

van Ommen, Fasco
le Quellenec, Gaelle A T
Willemsen-Bosman, Mirjam E
Van Noesel, Max M.
van den Heuvel-Eibrink, Marry MISNI 0000000394733717
Seravalli, EnricaORCID 0000-0001-5983-2256ISNI 0000000047208248
Kroon, Petra S
Janssens, Geert O.ORCID 0000-0002-0331-713X

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

BACKGROUND: In pediatric radiotherapy treatment planning of abdominal tumors, dose constraints to the pancreatic tail/spleen are applied to reduce late toxicity. In this study, an analysis of inter- and intrafraction motion of the pancreatic tail/spleen is performed to estimate the potential benefits of online MRI-guided radiotherapy (MRgRT). MATERIALS AND METHODS: Ten randomly selected neuroblastoma patients (median age: 3.4 years), irradiated with intensity-modulated arc therapy at our department (prescription dose: 21.6/1.8 Gy), were retrospectively evaluated for inter- and intrafraction motion of the pancreatic tail/spleen. Three follow-up MRIs (T2- and T1-weighted ± gadolinium) were rigidly registered to a planning CT (pCT), on the vertebrae around the target volume. The pancreatic tail/spleen were delineated on all MRIs and pCT. Interfraction motion was defined as a center of gravity change between pCT and T2-weighted images in left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) direction. For intrafraction motion analysis, organ position on T1-weighted ± gadolinium was compared to T2-weighted. The clinical radiation plan was used to estimate the dose received by the pancreatic tail/spleen for each position. RESULTS: The median (IQR) interfraction motion was minimal in LR/AP, and largest in CC direction; pancreatic tail 2.5 mm (8.9), and spleen 0.9 mm (3.9). Intrafraction motion was smaller, but showed a similar motion pattern (pancreatic tail, CC: 0.4 mm (1.6); spleen, CC: 0.9 mm (2.8)). The differences of Dmean associated with inter- and intrafraction motions ranged from - 3.5 to 5.8 Gy for the pancreatic tail and - 1.2 to 3.0 Gy for the spleen. In 6 out of 10 patients, movements of the pancreatic tail and spleen were highlighted as potentially clinically significant because of ≥ 1 Gy dose constraint violation. CONCLUSION: Inter- and intrafraction organ motion results into unexpected constrain violations in 60% of a randomly selected neuroblastoma cohort, supporting further prospective exploration of MRgRT.

Keywords

Interfraction motion, MRI-guided radiotherapy, Neuroblastoma, Pediatric radiotherapy, Intrafraction motion, Oncology, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Van Ommen, F, le Quellenec, G A T, Willemsen-Bosman, M E, van Noesel, M M, van den Heuvel-Eibrink, M M, Seravalli, E, Kroon, P S & Janssens, G O 2023, 'MRI-based inter- and intrafraction motion analysis of the pancreatic tail and spleen as preparation for adaptive MRI-guided radiotherapy in neuroblastoma', Radiation Oncology [E], vol. 18, no. 1, 160. https://doi.org/10.1186/s13014-023-02347-9