Real-time dose reconstruction and dose coverage forecasting using the magnetic resonance linear accelerator

Publication date

2026-01

Authors

Stijnman, Peter R.S.
Borman, Pim
Oolbekkink, Stijn
Zachiu, Cornel
Fast, Martin FORCID 0000-0001-9107-4627
Raaymakers, Bas WORCID 0000-0002-8036-6808ISNI 0000000392005337

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background and purpose: Intrafraction patient motion during radiotherapy treatment affects the delivered dose, thereby, deviating from the planned dose. To monitor the deviation, we propose a workflow capable of performing and displaying real-time dose calculations during treatment with a magnetic resonance linear accelerator (MR-linac). Additionally, the workflow can forecast the accumulated dose and enables evaluation of dose guidance in real time for triggering automatic plan adaptation or intrafraction drift corrections (IDCs). Materials and methods: Information on the treated anatomy, rigid translations or three-dimensional (3D) volumes, and the linac state were collected to perform clinical grade dose calculations. Real-time dose reconstructions and the accumulated dose forecasts were performed for two dynamic scenarios. The first, rigid translations derived from two-dimensional orthogonal MR images where the calculated dose was compared to diode measurements. The second, deformable dose accumulation using deformable image registration, based on 3D MR imaging and compared to a dose film measurement. Results: The real-time dose reconstruction had a maximum standard deviation error of 2.3 % with the measured dose, compared to 13.1 % for the planned dose. The workflow maintained real-time performance using a single graphics processing unit up to 92 % of the time that the beam was on. Finally, dose coverage forecasts were updated every 6.5 s at the start of treatment, with the update frequency increasing towards the end of treatment. Conclusion: We demonstrated the feasibility of displaying real-time delivered dose distributions and forecasted dose coverage using an MR-Linac. This enables triggering automatic plan adaptations or IDCs.

Keywords

Dose evaluation, Image-guided radiotherapy, Real-time, Radiation, Oncology, Radiology Nuclear Medicine and imaging

Citation

Stijnman, P R S, Borman, P T S, Oolbekkink, S, Zachiu, C, Fast, M F & Raaymakers, B W 2026, 'Real-time dose reconstruction and dose coverage forecasting using the magnetic resonance linear accelerator', Physics and Imaging in Radiation Oncology, vol. 37, 100910. https://doi.org/10.1016/j.phro.2026.100910