Variation in perioperative cerebral and hemodynamic monitoring during carotid endarterectomy

Publication date

2021-11

Authors

Fassaert, Leonie M M
Toorop, R. J.ISNI 0000000392335889
Petri, Bart-Jeroen
Westerink, J.ISNI 0000000388385904
van Hattum, Eline S
Kappelle, JaapISNI 0000000389941458
Kappelle, JaapISNI 0000000389941458
van Klei, W. A.ISNI 0000000396755004
de Borst, Gert JISNI 0000000396922458

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background: Hemodynamic disturbances cause half of the perioperative strokes following carotid endarterectomy (CEA). Guidelines strongly recommend strict pre- and postoperative blood pressure (BP) monitoring in CEA patients, but do not provide firm practical recommendations. Although in the Netherlands 50 centres perform CEA, no national protocol on perioperative hemodynamic, and cerebral monitoring exists. To assess current monitoring policies of all Dutch CEA-centres, a national survey was conducted. Methods: Between May and July 2017 all 50 Dutch CEA-centres were invited to complete a 42-question survey addressing perioperative hemodynamic and cerebral monitoring during CEA. Nonresponders received a reminder after 1 and 2 months. By November 2017 the survey was completed by all centres. Results: Preoperative baseline BP was based on a single bilateral BP-measurement at the outpatient-clinic in the majority of centres (n = 28). In 43 centres (86%) pre-operative monitoring (transcranial Doppler (TCD, n = 6), electroencephalography (EEG, n = 11), or TCD + EEG (n = 26)) was performed as a baseline reference. Intraoperatively, large diversity for type of anaesthesia (general: 45 vs. local [LA]:5) and target systolic BP (>100 mm hg – 160 mm hg [n = 12], based on preoperative outpatient-clinic or admission BP [n = 18], other [n = 20]) was reported. Intraoperative cerebral monitoring included EEG + TCD (n = 28), EEG alone (n = 13), clinical neurological examination with LA (n = 5), near-infrared spectroscopy with stump pressure (n = 1), and none due to standard shunting (n = 3). Postoperatively, significant variation was reported in standard duration of admission at a recovery or high-care unit (range 3–48 hr, mean:12 hr), maximum accepted systolic BP (range >100 mm hg – 180 mm Hg [n = 32]), postoperative cerebral monitoring (standard TCD [n = 16], TCD on indication [n = 5] or none [n = 24]) and in timing of postoperative cerebral monitoring (range directly postoperative – 24 hr postoperative; median 3 hr). Conclusions: In Dutch centres performing CEA the perioperative hemodynamic and cerebral monitoring policies are widely diverse. Diverse policies may theoretically lead to over- or under treatment. The results of this national audit may serve as the baseline dataset for development of a standardized and detailed (inter)national protocol on perioperative hemodynamic and cerebral monitoring during CEA.

Keywords

Carotid endarterectomy, Cerebral monitoring, Hemodynamics, National survey, Perioperative care, Surgery, Cardiology and Cardiovascular Medicine

Citation

Fassaert, L MM, Toorop, R J, Petri, B J, Westerink, J, van Hattum, E S, Kappelle, L J, Kappelle, L J, van Klei, W A & de Borst, G J 2021, 'Variation in perioperative cerebral and hemodynamic monitoring during carotid endarterectomy', Annals of Vascular Surgery, vol. 77, pp. 153-163. https://doi.org/10.1016/j.avsg.2021.06.015