ER-detect: a pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data

Publication date

2025-06

Authors

van den Boom, Max A
Gregg, Nicholas M
Valencia, Gabriela Ojeda
Lundstrom, Brian N
Miller, Kai J
van Blooijs, Dorien
Huiskamp, Geertjan MISNI 0000000389847234
Leijten, FransORCID 0000-0003-2603-3364ISNI 0000000396446949
Worrell, Gregory A
Hermes, Dora

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

BACKGROUND: Human brain connectivity can be measured in different ways. Intracranial EEG (iEEG) measurements during single pulse electrical stimulation provide a unique way to assess the spread of electrical information with millisecond precision. However, the methods used for the detection of responses in cortico-cortical evoked potential (CCEP) data vary across studies, from visual inspection with manual annotation to a variety of automated methods. NEW METHOD: To provide a robust workflow to process CCEP data and detect early evoked responses in a fully automated and reproducible fashion, we developed the Early Response (ER)-detect toolbox. ER-detect is an open-source Python package and Docker application to preprocess BIDS structured iEEG data and detect early evoked CCEP responses. ER-detect can use three early response detection methods, which were validated against 14 manually annotated CCEP datasets from two different clinical sites by four independent raters. RESULTS: and comparison with existing methods: ER-detect's automated detection performed on par with the inter-rater reliability (Cohen's Kappa of ~0.6). Moreover, ER-detect was optimized for processing large CCEP datasets, to be used in conjunction with other connectomic investigations. CONCLUSION: ER-detect provides a highly efficient standardized workflow such that iEEG-BIDS data can be processed in a consistent manner and enhance the reproducibility of CCEP based connectivity results for both research and clinical purposes.

Keywords

Automated detection toolbox, BIDS, Cortico-cortical evoked potential (CCEP), Early evoked responses, Intracranial EEG (iEEG), N1, Taverne, General Neuroscience, Journal Article

Citation

van den Boom, M A, Gregg, N M, Valencia, G O, Lundstrom, B N, Miller, K J, van Blooijs, D, Huiskamp, G J M, Leijten, F S S, Worrell, G A & Hermes, D 2025, 'ER-detect : a pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data', Journal of Neuroscience Methods, vol. 418, 110389. https://doi.org/10.1016/j.jneumeth.2025.110389